A simple, rapid and sensitive reversed-phase high-performance liquid chromatographic (HPLC) method for the measurement of mupirocin concentrations in both skin layers and percutaneous samples has been developed. Mupirocin was extracted from skin layers using PBS-acetonitrile (90:10, v/v). The method is sufficiently sensitive and repeatable to be used in percutaneous penetration studies. The samples were chromatographed on a 250x4 mm C 8 LiChrospher Select B (5 µm). The mobile phase composition was a mixture of acetonitrile-ammonium acetate 0.05 M (27.5:72.5, v/v) adjusted to pH 6.3 with acetic acid. The analyte was detected at 228 nm and the run time was 11 min. Linearity was confirmed in the concentration range 0.2-20 µg/ml and the limit of detection was 9.5 ng/ml.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.