Fracture distraction of more than three millimeters should not be tolerated when stabilizing tibial fractures with unreamed, small-diameter nails as this increases the odds of having a delayed union by twelve times (p < 0.001) and a nonunion by four times (p = 0.057). There was a significant increase of complications in the group of Grade III open fractures (p < 0.001), AO/OTA Type C fractures (p = 0.002), and to a lesser extent in distal fractures. However, the rate of severe complications resulting in major morbidity was low.
Although many studies describe the endoprosthetic replacement as the safer method to treat pathologic femur fractures, our data showed that intramedullary stabilization and endoprosthetic replacement to be safe, and equivalent alternatives to treat complete pathologic fractures of the femur in patients with advanced metastatic disease.
With regards to fracture healing and functional outcome of the patients, we had a satisfactory outcome after angular stable plate fixation of proximal humeral fractures. However, we experienced a notably high rate of technical failures and partial humeral head necrosis. Advanced surgical skills and experiences are necessary to achieve correct anatomic reduction and implant fixation, to reduce the risk of these treatment-related complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.