The material properties of articular cartilage in the rabbit tibial plateau were determined using biphasic indentation creep tests. Cartilage specimens from matched-pair hind limbs of rabbits approximately 4 months of age and greater than 12 months of age were tested on two locations within each compartment using a custom built materials testing apparatus. A three-way ANOVA was used to determine the effect of leg, compartment, and test location on the material properties (aggregate modulus, permeability, and Poisson's ratio) and thickness of the cartilage for each set of specimens. While no differences were observed in cartilage properties between the left and right legs, differences between compartments were found in each set of specimens. For cartilage from the adolescent group, values for aggregate modulus were 40% less in the medial compartment compared to the lateral compartment, while values for permeability and thickness were greater in the medial compartment compared to the lateral compartment (57% and 30%, respectively). Values for Poisson's ratio were 19% less in the medial compartment compared to the lateral compartment. There was also a strong trend for thickness to differ between test locations. Similar findings were observed for cartilage from the mature group with values for permeability and thickness being greater in the medial compartment compared to the lateral compartment (66% and 34%, respectively). Values for Poisson's ratio were 22% less in the medial compartment compared to the lateral compartment.
Methods of producing relevant and quantifiable load alterations in vivo with which to study loadinduced cartilage degeneration analogous to osteoarthritis are limited. An animal model was used to investigate the effects of increased chronic loads on articular cartilage. Mature rabbits were randomized into one of three experimentally-loaded groups and a fourth unoperated control group. A mechanical-loading device was skeletally fixed to the hind limb of animals in the loaded groups. Engaging the device resulted in an additional load of 0, +22 or +44% body weight to the medial compartment of the experimental knee while allowing normal joint function. Following a 12-week loading protocol, a creep indentation test and needle probe test were used to determine the biphasic material properties and thickness of the cartilage at four locations of each femoral and tibial condyle of the experimental and contralateral limbs. Analyses of covariance were performed to compare outcome measures across treatment groups. The effect of increased load was site and load-level specific with alterations of materialproperties and thickness most prominent in the posterior region of the medial compartment of the tibia. At this site, permeability increased 128% and thickness increased 28% in the +44% body weight group relative to the 0% body weight group. This model of altered chronic loading initiated changes in material properties to the articular cartilage at the sites of increased load over 12-weeks that were consistent with early degenerative changes suggesting that increased tibio-femoral loading may be responsible for the alterations. This work begins to elucidate the chronic load threshold and the time course of cartilage degeneration at different levels of altered loading.
The flow, setting, and aging characteristics of a newly developed calcium phosphate/calcium aluminate composite orthopaedic cement were studied. The effect of vibration on the flow of the cement paste was studied and found to greatly enhance placement. The setting times of this cement were dependent on temperature and decreased with increasing temperatures. At 37 degrees C, the working and setting times were 6.3 +/- 0.3 and 12.8 +/- 0.4 minutes, respectively. Hydration and conversion of the cement phases continued while specimens were stored under simulated, physiological conditions. A cumulative increase in mass of 8.23 +/- 0.65% was observed over a 14 month test period. During this time, the cement was found to expand slightly, 0.71 +/- 0.39%. X-ray diffraction was used to characterize the crystalline phases present during hydration and conversion. The calcium aluminate in the cement hydrated and formed calcium aluminate chloride hydrates, while no changes were observed in the beta-tricalcium phosphate during the testing period.
Objective We investigated the relationship between the magnitude and duration of sustained compressive load alteration and the development of degenerative changes in the rat tibiofemoral joint. Methods A varus loading device was attached to the left hind limb of mature rats to apply increased compression to the medial compartment and decreased compression to the lateral compartment of the tibiofemoral joint of either 0% or 100% body weight for 0, 6 or 20 weeks. Compartment-specific assessment of the tibial plateaus included biomechanical measures (articular cartilage aggregate modulus, permeability and Poisson’s ratio, and subchondral bone modulus) and histological assessments (articular cartilage, calcified cartilage, and subchondral bone thicknesses, degenerative scoring parameters, and articular cartilage cellularity). Results Increased compression in the medial compartment produced significant degenerative changes consistent with the development of osteoarthritis including a progressive decrease in cartilage aggregate modulus (43% and 77% at 6 and 20 weeks), diminished cellularity (38% and 51% at 6 and 20 weeks), and increased histological degeneration. At 20 weeks, medial compartment articular cartilage thickness deceased 30% while subchondral bone thickness increased 32% and subchondral bone modulus increased 99%. Decreased compression in the lateral compartment increased calcified cartilage thickness, diminished region-specific subchondral bone thickness and revealed trends for reduced cellularity and decreased articular cartilage thickness at 20 weeks. Conclusions Altered chronic joint loading produced degenerative changes consistent with those observed clinically with the development of osteoarthritis and may replicate the slow development of non-traumatic osteoarthritis in which mechanical loads play a primary etiological role.
Summary We investigated the relationship between the magnitude and duration of chronic compressive load alteration and the development and progression of degenerative changes in the rabbit tibiofemoral joint. Varus loading devices were attached to the hind limb of mature NZW rabbits. Altered compressive loads of 0, 50 and 80% body weight (BW) were applied to the tibiofemoral joint for 12 hours per day for 12 and 24 weeks (n=4 animals/group). Compartment-specific assessment of the tibial plateau included histological assessments (articular cartilage, calcified cartilage, and subchondral bone thicknesses, degeneration score, and articular cartilage cellularity) and biomechanical measures (aggregate modulus, permeability, Poisson's ratio). Analyses of variance techniques were used to examine the relationship between each outcome measure with load magnitude and duration as independent variables in the model. Degenerative changes developed in the medial compartment with increased magnitude of compressive loading and included fibrillation, increased degeneration score, and reduced cellularity of the articular cartilage. Increased calcified cartilage thickness was observed in both the medial and lateral compartments following exposure to altered loading of 80% BW for 24 weeks. This work demonstrates that in vivo chronic compressive load alteration to the tibiofemoral joint can initiate progressive macroscopic and histological-based degenerative changes analogous to the early changes occurring in OA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.