Slope failure is a complex phenomenon that may caused to landslides. Buildings and infrastructure such as transportation facilities and pipelines located within the boundaries of a landslide can be damaged or destroyed. Slope failure classification and various factors contributing to the instability using 2-D resistivity survey conducted in Selangor, Malaysia are described. Six 2-D resistivity survey lines with 5 m minimum electrode spacing using Pole-dipole array were performed. The data were processed using Res2Dinv and surfer10 software to evaluate the subsurface characteristics. The 2-D resistivity results show that the subsurface consist of two main zones. The first zone was alluvium or highly weathered with resistivity value of 100-1000 O m and depth of >30 m. This zone consists of saturated area with resistivity value of 1-100 O m and boulders with resistivity value of 1200-7000 O m. The second zone with resistivity value of >7000 O m was interpreted as granitic bedrock. The study area was characterized by saturated zones, highly weathered zone, highly contain of sand and boulders that will trigger slope failure in the survey area. This will cause to low strength of soil, debris flow and movement of earth. On the basis of the case examples described, 2-D resistivity method is categorized into desirable and useful method in determination of slope failure and future assessments.
Water seepage erosion has been and remains one of the major engineering problems. However, most engineers will much depend on borehole data and soil test for designing and problem detection. By considering of the cost and destructive method, selection of geoelectrical prospecting would be appropriate. Therefore, two electrical geophysical surveys were carried out in Sekolah Menengah Kebangsaan Dato' Haji Mohd Nor, Gelugor, Pulau Pinang to map the presence of the unknown underground water sources (saturated zones) and its movement. With the total of seven resistivity lines parallel to each other and self potential (SP) with 5 m × 5 m gridding survey were successfully done. The resistivity result from line 1 (R1) to line 6 (R6) shows the subsurface consist of saturated zones with range between 3 m up to 10 m depth, before it reaches the R7 which is believed as the accumulation zone. Meanwhile, as for SP result it shows the water flow from higher value (north-east) towards the lower value which is mostly at the south area. In conclusion, geoelectrical survey could assist in detecting and solving engineering problems as it proven by the result from each method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.