A new instrument, the Fugatron, is presented that was developed to make in situ measurements of dissolved hydrogen concentrations in laboratory reactors. The principle of measurement is based on a probe with a tip that consists of a small porous metal substrate coated with a dense layer of fluoropolymer. The probe is exposed to the liquid phase and is internally purged by a constant flow of carrier gas. Driven by the hydrogen concentration gradient between the external and internal side of the composite layer, the hydrogen molecules permeate into the carrier gas stream. The concentration of the permeate in the carrier gas stream is measured by a gas analyzer. The analyzer signal is proportional to the partial pressure of dissolved gas. The steady-state concentration of dissolved hydrogen in the liquid is calculated from the analyzer signal by using solubility data. Calibration methods are described for immersion probes used for in situ measurements in reactors which are operated in batch or continuous mode as well as for flow-through probes used for liquid stream analysis. The sensitivity of the instrument and the reliability of the measurements were tested in different solutions as a function of temperature and pressure. The hydrogenation of an alkyne with a suspended palladium catalyst was chosen as a model reaction for in situ measurements. The hydrogenation experiments were carried out in a 0.5-L stirred-tank reactor with a turbine stirrer in a semibatch mode. Initial hydrogen uptake rates and dissolved hydrogen concentrations during this model reaction were measured as a function of the amount of catalyst in the liquid. The solubility of hydrogen in the pure liquid was determined by a gas absorption measurement at reaction conditions. From these measurements, the volumetric liquid-side mass transfer coefficient k L a at the gas−liquid interface was calculated as a function of catalyst loading. In addition, the k L a value was also determined in the absence of solid particles by the dynamic pressure drop method. Discrepancies that may result from calculating steady-state dissolved hydrogen concentrations using k L a values obtained from measurements conducted either in pure liquids or in liquids that contain suspended catalyst particles are discussed and illustrated by these measurements. The new method allows direct measurement of the concentrations of dissolved gases during a reaction, which can be a decisive factor for the rate as well as for the selectivity of a process. Estimations of the gas concentrations via reaction rate data and cumbersome determinations of k L a values are, therefore, no longer necessary.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.