<p><span lang="EN-US">The Kainji hydropower station is a seven turbo-alternator station that for many years served as the base load supply for the Nigerian power grid. Over 200,000 pieces of data about the performance of the machines were used to estimate values of the failure and repair rates for each machine and a Markov steady-state model of the plant was constructed to determine the probability output of the turbines. This result showed that Kaplan turbine (KT) 12 is prone to failure compared to any other KT unit in the hydropower plant. Also, the clusters of probability that define the system state due to the different output capacities of the units show that the hydropower plant has not performed to its maximum capacity, further evaluation shows that 60% of the KT machine units are operating which is consistent with the observed robustness of the output. The model not only conforms to observations but reasonably provide a means of studying the effects of different actions that may be taken to improve the performance of hydropower plant.</span></p>
This study evaluated lightning protective system efficacy on 11kV-132kV substation-power line installation in Ikorodu, Lagos State, Nigeria with reference to cloud to ground(C-G) lightning strike (LS) events. It focus on interception of lightning strikes and its protection with reference to direct lightning strike (DLS) and indirect lightning strike (IDLS). Data were collected from Ikorodu 132/33 kV Transmission Substation and its four major injection stations. This work was carried out using physical measurement of raw data obtained from the high voltage substation. Installations were scaled down and modelled dimensionally using AutoCAD software in order to measure spatial parameters in order to measure the screening of the existing substations and connected lines, as well as the existing cone angles of protection. Probability of lightning efficiency of lightning protective level (LPL) are used for screening evaluation while spike and sky wire angle of protection are used for cone of protection evaluation. Physical measurement of six substations (33/11 kV and 132/33 kV substations) in the studied area were also carried out to evaluate the effectiveness of the installed lightning arresters with respect to the protected devices using applicable standard. The results under the prevailing lightning protective system, LPS, (screening method), revealed that the existing 33/11 kV and 132/33 kV substations are not adequately protected against lightning strike; 132/33 kV substation is more vulnerable to lightning strike than 33/11kV substation and that the incoming 132kV power lines to the substation are adequately protected. The evaluation of the installed distances of all lightning arresters are within standard range and would adequately protect substation transformers against travelling waves (Indirect Stroke) events. The installed lightning arresters (LAs) would adequately protect substation transformers against travelling waves (Indirect Stroke) events. The adequate protection should be reinforced with proposed design scheme in further study in order to mitigate the disastrous effects of lightning strike. Any proposed design of protective system for electric power installations in Nigeria should be simulated using computer aided design software for scaled validation of dimensional and spatial design values in order to mitigate reported failures and uncertainties in identifying causes of observed failures in the system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.