We used Doppler echocardiography to quantitate the changes in intracardiac blood flow velocities and right and left ventricular stroke volumes in 80 normal human fetuses from 19 to 40 weeks gestation. Blood flow velocity spectra across the aortic, pulmonary, tricuspid, and mitral valves were digitized to obtain peak velocities (m/sec) and flow velocity integrals. Aortic and pulmonary diameters were measured at valve level from two-dimensional echocardiographic images and cross-sectional area was calculated assuming a circular orifice. Ventricular stroke volume was calculated as the product of the cross-sectional area of a great vessel and the flow velocity integral through that vessel. The pulmonary arterial and aortic diameters increased linearly with gestational age (r = .82, r = .84), and pulmonary arterial diameter consistently exceeded aortic diameter. There was a positive relationship between stroke volume and gestational age: stroke volume increased exponentially from 0.7 ml at 20 weeks to 7.6 ml at 40 weeks for the right ventricle (r = .87) and from 0.7 ml at 20 weeks to 5.2 ml at 40 weeks for the left ventricle (r = .91). Similar results were obtained for right and left ventricular and combined cardiac outputs. In 44% of the fetuses it was possible to quantitate both right and left ventricular stroke volumes. There was a close correlation between right and left ventricular stroke volumes in these fetuses (r = .96) and right ventricular stroke volume exceeded left ventricular stroke volume by 28%. Flow velocity across the tricuspid and mitral valves was consistently greater during atrial systole (A wave) than during rapid ventricular filling (E wave) (0.52 0.07 vs 0.37 + 0.08 m/sec and 0.45 ± 0.07 vs 0.33 ± 0.06 mlsec). The E/A ratios for the mitral and tricuspid valves were similar throughout the period of gestation studied, indicating equivalent diastolic ventricular function. This study demonstrates that right and left ventricular stroke volumes increase by approximately 10-fold from 20 to 40 weeks gestation in the normal human fetus. It also demonstrates, within the limitations of the equipment, that right ventricular stroke volume exceeds that of the left ventricle, thus confirming right ventricular dominance in utero. Circulation 74, No. 6, 1208-1216 TWO-DIMENSIONAL echocardiographic imaging of the fetal heart has permitted accurate definition of intracardiac anatomy and characterization of the growth patterns of the four cardiac chambers throughout the second and third trimesters.'-Echocardiography has also enabled recognition of cardiac rhythm distur-
A prospective study was performed in 340 obstetric sonograms to evaluate the sonographic characteristics of the fetal thymus. The thymus was identified as a homogeneous structure in the anterior fetal mediastinum in 251 cases (74%). The thymus was categorized as either hyperechoic, isoechoic, or hypoechoic relative to fetal lung. Seventy one of 115 cases (62%) prior to 27 weeks gestation were hyperechoic relative to fetal lung whereas T he normal thymus is relatively large at birth and is easily visible with a standard chest radiograph or computed tomography. 1 Although the appearance of the infant thymus has been described extensively using several imaging modalities including ultrasound, 2 .3 we know of no report describing the sonographic appearance of the fetal thymus. The purpose of this paper is to describe the sonographic appearance of the normal fetal thymus and to report our experience with imaging it. METHODSWe prospectively evaluated the fetal thymus in 340 consecutive normal obstetric sonograms between 14 weeks gestation and term. Dating of each pregnancy was based on multiple fetal growth parameters, 4 earlier ultrasound if available, or reliable menstrual history. The frequency of sonographic visualization of the thymus was assessed. Only if well-defined borders could be seen be-
To determine the embryonic size at which cardiac activity is always seen in a normal early pregnancy, 398 endovaginal sonograms were evaluated in which the gestational sac contained a yolk sac and/or embryo of less than or equal to 12 mm in crown-rump length (CRL). In the 99 sonograms in which there was a yolk sac but no identifiable embryo, cardiac activity was absent in 75; 58 of these pregnancies progressed normally. Of the 299 sonograms where there was an identifiable embryo with CRL less than or equal to 12 mm, cardiac activity was absent in 31; 29 of these were proven to be failed pregnancies. In two cases the pregnancy progressed normally; the CRL was 2 mm in one case and 4 mm in the other. We conclude that once an embryo is seen by endovaginal sonography, the absence of cardiac activity usually indicates embryonic demise. However, when cardiac activity is absent, one should refrain from definitively diagnosing embryonic demise, based on a single sonogram, if the CRL is less than 5 mm.
The authors compared the diagnostic yield of endovaginal color and pulsed Doppler ultrasound (US) in conjunction with endovaginal sonography with that of endovaginal sonography alone in patients prescreened to be at increased risk for ectopic pregnancy. Pelvic structures were evaluated for overall vascularity and for the presence of characteristic pulsed Doppler US velocity waveforms. The diagnostic sensitivity of the initial endovaginal sonographic examination increased with the addition of color and pulsed Doppler US, from 71% to 87% for ectopic pregnancy, from 24% to 59% for failed intrauterine pregnancy, and from 90% to 99% for viable intrauterine pregnancy. Specificities for endovaginal sonography with color and pulsed Doppler US ranged from 99% to 100%. Use of endovaginal color and pulsed Doppler US increased the percentage of diagnostic initial sonographic examinations from 62% to 82%. The improved diagnostic sensitivity of endovaginal color Doppler US for ectopic pregnancy may ultimately result in earlier treatment, with reduced morbidity and mortality.
Anomalies of systemic and pulmonary venous return are found as either isolated lesions or as part of a complex cardiac malformation. Specifically, these venous pathway malformations are associated frequently with the cardiac defects in asplenia or polysplenia. This report describes the prenatal ultrasound diagnosis of both anomalous pulmonary and systemic venous drainage in three late gestation fetuses with a splenic syndrome and complex congenital heart disease. In addition, the utility of color-flow Doppler as an aid in making the diagnosis is emphasized.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.