CRT Survey II provides a valuable source of information on contemporary clinical practice with respect to CRT implantation in a large sample of ESC member states. The survey permits assessment of guideline adherence and demonstrates variations in patient selection, management, implantation procedure and follow-up strategy.
The incidence of cardiac perforation related to pacing and defibrillation leads is low. The use of active fixation leads is associated with an increased risk of cardiac perforation. We did not find any correlation between the perforation rate and any particular model of the implanted lead.
Background
To date, there are no data from randomized controlled studies on the benefit of cardiac resynchronization therapy (CRT) when implanted as an upgrade in patients with a previous device as compared to de novo CRT. In the CRT Survey II we compared the baseline data of patients upgraded to CRT (CRT‐P/CRT‐D) from a previous pacemaker (PM) or implantable cardioverter‐defibrillator (ICD) to de novo CRT implantation.
Methods and results
In the European CRT Survey II, clinical practice data of patients undergoing CRT and/or ICD implantation across 42 European Society of Cardiology (ESC) countries were collected between October 2015 and December 2016. Out of a total of 11 088 patients, 2396 (23.2%) were upgraded from a previous PM or ICD and 7933 (76.8%) underwent de novo implantation. Compared to de novo implantations, upgraded patients were older, more often male, more frequently had ischaemic heart failure aetiology, atrial fibrillation, reduced renal function, worse heart failure symptoms, and higher N‐terminal pro‐B‐type natriuretic peptide levels. Upgraded patients were more often PM‐dependent and less frequently received CRT‐D. Total peri‐procedural, in‐hospital complications and length of hospital stay were similar. Upgraded patients were less frequently treated with heart failure medication at discharge.
Conclusion
Despite a lack of evidenced‐based data, close to one quarter of all CRT implantations across 42 ESC countries were upgrades from a previous PM or ICD. Despite older age and worse symptoms, the CRT implantation procedures in upgraded patients were equally frequently successful and complications similar to de novo implantations. These results call for more studies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.