Objectives
To determine the ultrastructural changes of titanium surfaces of dental implants induced by the tip of periodontal probes.
Materials and methods
A total of 40 samples of smooth and rough surfaces of titanium implants were randomly assigned for the treatment with metal or plastic periodontal probes under application angles of 20° and 60°. Titanium surfaces have been evaluated with CLSM prior and following to experimental probing determining various standardized 2D and 3D roughness parameters.
Results
The average profile and surface roughness (Ra and Sa) showed no significant difference between treated and untreated samples on smooth and rough surface areas irrespective of the probe material. On smooth surfaces several amplitude roughness parameters were increased with metal probes but reached significance only for Rp (p = 0.007). Rough surface parts showed a slight but not significant reduction of roughness following to the contact with metal probes. The surface roughness remained almost unchanged on smooth and rough implant surfaces using plastic probes. The surface roughness on implant surfaces was not dependent on the application angle irrespective of the probe material.
Conclusion
Probing of titanium implants with metal probes and even less with plastic probes causes only minor changes of the surface roughness. The clinical significance of these changes remains to be elucidated.
Clinical relevance
Using plastic probes for the clinical evaluation of the peri-implant sulcus might avoid ultrastructural changes to titanium implant surfaces.
Purpose
To determine the clinical and radiological outcomes of hybrid-design- (HD) and bone-level (BL) implants for bar-retained mandibular implant-overdentures (IODs).
Methods
For this retrospective study, edentulous patients who had received maxillary complete dentures and mandibular bar-retained IODs were invited for a follow-up assessment. Implant survival, implant success and health of peri-implant tissues were assessed on an implant level-based analysis. Patient-based parameters served to identify risk factors for peri-implant bone loss, presence of peri-implantitis and success.
Results
Eighty patients (median age 72.72 [67.03; 78.81] years, 46 females) with 180 implants (median follow-up 12.01 [10.82; 21.04] years) were assessed. There was no difference concerning the rate of implant failure (p = 0.26), or peri-implantitis (p = 0.97) between HD and BL implants. Solely in one study group, there was the presence of peri-implant pus. Implant success was higher in BL implants with one group being notably higher than the comparing groups (p = 0.045). For bone loss, a width of keratinized mucosa (KM) ≤ 1 mm (p = 0.0006) and the presence of xerostomia (p = 0.09) were identified as risk factors. Smoking (p = 0.013) and a higher body mass index (BMI) (p = 0.03) were a risk factor for peri-implantitis. As risk factors for reduced implant success, a small width of KM (p = 0.003) and the presence of xerostomia (p = 0.007) were identified.
Conclusions
For mandibular bar-retained IODs, both BL and HD implants are mostly successful. A minimum of 1 mm KM around implants and normal salivary flow are relevant factors for implant success and stable peri-implant bone levels. Smoking and a high BMI are potential risk factors for peri-implantitis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.