Traditional estimation of sulcus size through limbal measurement is inadequate because limbus size alone cannot predict sulcus size. A general formula using the sphere and the mean corneal power can help predict sulcus size. Corneal power was significantly and negatively correlated with sulcus and limbus size as well as sphere. The standard error of sulcus measurement by UBM was 0.4 mm.
Purpose To review causes for performing an ultrasound biomicroscopic (UBM) examination in traumatized eyes, to present common UBM findings of 109 eyes with a history of ocular trauma and to compare these findings according to the type of the trauma. Materials and methods A total of 109 eyes with a history of mechanical ocular trauma, which underwent an UBM examination between December 1996 and April 2002, were evaluated retrospectively. All cases were classified according to the criteria of the Ocular Trauma Classification Group and UBM findings were reviewed. For statistical analyses, v 2 test and Fisher's exact test were used. Results UBM examinations were performed for the evaluation of the zonules before cataract surgery (49.5%), examination of the anterior segment in the presence of media opacities (32.1%), detection of suspected ocular foreign bodies (10.1%) and the evaluation of ocular hypotony (8.3%). In all, 67 eyes (61.5%) had a closed-globe injury, whereas 42 (38.5%) had an open-globe injury. The most common UBM findings in a closed-globe injury were zonular deficiency (64.2%), angle recession (43.3%), iridodialysis (17.9%), and dislocated lens (16.4%). The most common UBM findings in an open-globe injury were zonular deficiency (54.8%), iridodialysis (26.2%), peripheral anterior synechiae (PAS) (26.2%), and iridocorneal adhesion (19%). Among the common UBM findings, the angle recession was significantly higher (Po0.001) in closedglobe injury group and PAS formation was significantly higher (Po0.05) in open-globe injury group. Conclusions UBM is particularly superior to other methods in the evaluation of the zonular status, angle recession, cyclodialysis, and the detection of small superficial and intraocular foreign bodies.
Adequate space was maintained between the Artisan hyperopic IOL and the corneal endothelium, angle, and crystalline lens. Haptic indentation of the iris, which could lead to pigment erosion, was observed. Preoperative gonioscopy and maintenance of normal intraocular pressure postoperatively suggest the indentation was secondary to inadequate lens vaulting relative to the high natural arch of the iris in hyperopic eyes. Shortening the haptics or increasing the lens vault might resolve this problem.
Vitreous shaving of sclerotomy sites using depressed vitrectomy significantly reduces vitreous incarceration. This may reduce the rate of sclerotomy-related complications following PPV in selected cases.
Irritation of ocular tissues by an IOL was the main cause of chronic postoperative noninfectious inflammation in pseudophakic eyes. Therefore, detecting the IOL position and its relationships to ocular tissues is very important in planning the treatment. Ultrasound biomicroscopy is a practical method that accurately provides this information.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.