Experimentally investigates heat dissipation by different longitudinal fins fitted to a cylindrical heat sink under natural convection conditions. Five aluminum fin configurations at base temperatures (70°C, 85°C, 100°C, and 115°C) were studied. The first fin was plain (fin1), while second fin had a triangular edge (fin2). The rest fins have the same triangular edge but with six 1cm circular perforations near the edge (fin3). While the perforations in fin4 were in the middle longitudinal fin length. The last fin (fin5) had twelve 0.5 cm circular perforations distributed into two columns. The measurements were validated with theoretical correlation with an acceptable deviation. The results showed that fin2, fin3, fin4, and fin5 dissipate more heat by 2.4%, 8.7%, 11.4%, and 5% than the flat fin with 9.8%, 11.85%, 11.85%, and 10.82% weight reduction, respectively. The heat transfer coefficient enhanced by 7.98%, 16.81%, 12.35%, and 5.44% for fin5, fin4, fin3, and fin2, respectively. Large circular perforation was more effective to dissipate heat especially when located near the heat source as in fin4 which gives the best heat dissipation with more weight reduction. The proposed fins efficiency were greater than 92%.
An experimental investigation has been made to study the influence of using v-corrugated aluminum fin on heat transfer coefficient and heat dissipation in a heat sink. The geometry of fin is changed to investigate their performance. 27 circular perforations with 1 cm diameter were made. The holes designed into two ways, inline arrangement and staggered in the corrugated edges arrangement. The experiments were done in enclosure space under natural convection. Three different voltages supplied to the heat sink to study their effects on the fins performance. All the studied cases are compared with v-corrugated smooth solid fin. Each experiment was repeated two times to reduce the error and the data recorded after reaching the steady state conditions. The results showed that the v-corrugated fin dissipate heat twice and triple times than flat plate mentioned in past research with the same dimension. Also, the inline perforated fin gave higher enhancement percentage than solid one by 15, 32 and 36% for 110, 150 and 200 V voltages supplied. Finally, the staggered perforation arrangement gave the higher enhancement percentage with 22, 42 and 45% for the same voltages supply.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.