The proposed classification reflects the degree of difficulty in designing and manufacturing of implants and can be very useful when comparing treatment results of skull defects for clinical or scientific purposes.
The purpose of this article is to describe a technique for secondary reconstruction of traumatic orbital wall defects using titanium implants that act as three-dimensional (3D) puzzle pieces. We present three cases of large defect reconstruction using implants produced by Xilloc Medical B.V. (Maastricht, the Netherlands) with a 3D printer manufactured by LayerWise (3D Systems; Heverlee, Belgium), and designed using the biomedical engineering software programs ProPlan and 3-Matic (Materialise, Heverlee, Belgium). The smaller size of the implants allowed sequential implantation for the reconstruction of extensive two-wall defects via a limited transconjunctival incision. The precise fit of the implants with regard to the surrounding ledges and each other was confirmed by intraoperative 3D imaging (Mobile C-arm Systems B.V. Pulsera, Philips Medical Systems, Eindhoven, the Netherlands). The patients showed near-complete restoration of orbital volume and ocular motility. However, challenges remain, including traumatic fat atrophy and fibrosis.
Purpose
Corrective osteotomy of a malunited distal radius conventionally relies on 2D imaging techniques for alignment planning and evaluation. However, this approach results in suboptimal bone repositioning, which is associated with poor patient outcomes. In this case series, we evaluate the use of novel patient-specific plates (PSPs), which feature navigation and fixation of bone segments as preoperatively planned in 3D.
Methods
Ten participants with distal radius malunion underwent CT scans for preoperative alignment planning. Patient-specific guides and plates were designed, 3D-printed, and sterilized for use in corrective surgery of the distal radius. Pre- and postoperative results were compared in regard to clinical, functional, and radiographic outcomes.
Results
The application of a PSP was successful in 7 of the 10 cases. After treatment, the residual alignment error was reduced by approximately 50% compared with conventional treatment. The use of PSPs reduced pain significantly. Pre- and postoperative results were pooled and demonstrated significant correlations between: (1) pain and malpositioning, (2) the range of pro- and supination motion, the MHOQ score, the EQ-5D-5L score and dorsovolar angulation, and (3) MHOQ score and proximodistal translation.
Conclusion
The correlation between malalignment and MHOQ score, EQ-5D-5L score, pain, and range of motion shows that alignment should be restored as well as possible. Compared to the conventional approach, which relies on 2D imaging techniques, corrective osteotomy based on 3D preoperative planning and intraoperative fixation with a PSP has been shown to improve bone alignment and reduce pain.
Level of evidence
IV.
Use of patient-specific fixation plates is promising in corrective osteotomy of the distal radius. So far, custom plates were mostly shaped to closely fit onto the bone surface and ensure accurate positioning of bone segments, however, without considering the biomechanical needs for bone healing. In this study, we investigated how custom plates can be optimized to stimulate callus formation under daily loading conditions. We calculated implant stress distributions, axial screw forces, and interfragmentary strains via finite element analysis (FEA) and compared these parameters for a corrective distal radius osteotomy model fixated by standard and custom plates. We then evaluated these parameters in a modified custom plate design with alternative screw configuration, plate size, and thickness on 5 radii models. Compared to initial design, in the modified custom plate, the maximum stress was reduced, especially under torsional load (− 31%). Under bending load, implants with 1.9-mm thickness induced an average strain (median = 2.14%, IQR = 0.2) in the recommended range (2–10%) to promote callus formation. Optimizing the plate shape, width, and thickness in order to keep the fixation stable while guaranteeing sufficient strain to enhance callus formation can be considered as a design criteria for future, less invasive, custom distal radius plates.
Graphical abstract
ᅟ
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.