Purpose:To compare torsional versus combined torsional and conventional ultrasound modes in hard cataract surgery regarding ultrasound energy and time and effect on corneal endothelium. Settings: Kasr El Aini hospital, Cairo University, and International Eye Hospital, Cairo, Egypt. Methodology: Ninety-eight eyes of 63 patients were enrolled in this prospective comparative randomized masked clinical study. All eyes had nuclear cataracts of grades III and IV using the Lens Opacities Classification System III (LOCS III). Two groups were included, each having an equal number of eyes (49). The treatment for group A was combined torsional and conventional US mode phacoemulsification, and for group B torsional US mode phacoemulsification only. Pre-and post-operative assessments included best corrected visual acuity (BCVA), intraocular pressure (IOP), slit-lamp evaluation, and fundoscopic evaluation. Endothelial cell density (ECD) and central corneal thickness (CCT) were measured preoperatively, 1 day, 7 days, and 1 month postoperatively. All eyes were operated on using the Alcon Infiniti System (Alcon, Fort Worth, TX) with the quick chop technique. All eyes were implanted with AcrySof SA60AT (Alcon) intraocular lens (IOL). The main phaco outcome parameters included the mean ultrasound time (UST), the mean cumulative dissipated energy (CDE), and the percent of average torsional amplitude in position 3 (%TUSiP3). Results: Improvement in BCVA was statistically significant in both groups (P , 0.001). Comparing UST and CDE for both groups revealed results favoring the pure torsional group (P = 0.002 and P , 0.001 for UST; P = 0.058 and P = 0.009 for CDE). As for %TUSiP3, readings were higher for the pure torsional group (P = 0.03 and P = 0.01). All changes of CCT, and ECD over time were found statistically significant using one-way ANOVA testing (P , 0.001). Conclusion: Both modes are safe in hard cataract surgery, however the pure torsional mode showed less US energy used.
PurposeTo evaluate the effect of lens status on intraocular pressure (IOP) in siliconized eyes and also on the emulsification of silicone oil.Patients and methodsA total of 31 eyes of 31 patients with retinal detachment were operated on with pars plana vitrectomy and silicone oil injection: 16 phakic (Group A) and 15 pseudophakic (Group B). During the 6-month follow-up period, IOP was measured: 1 day postoperative, then at 1 week, 1 month, 2 months, 3 months, and 6 months postoperative. At the end of the follow-up period, gonioscopy was carried out to check emulsified silicone at the anterior chamber angle and also the presence of emulsified silicone on the back of the cornea when the patient was lying down.ResultsThere was no significant difference between both groups until the first week (P value = 0.15). Starting from the first month, the difference was statistically significant, with mean IOPs in Groups A and B of 14.9 mmHg and 18.2 mmHg, respectively, up to the sixth month (P value = 0.002), with a mean IOP in Groups A and B of 14.4 mmHg and 19.4 mmHg, respectively. Emulsified silicone was clinically stated in twelve cases (80%) in Group B and in three cases (19%) in Group A.ConclusionThere is a higher incidence of increased IOP and emulsification of silicone oil in pseudophakic eyes than in phakic eyes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.