Standard electrochemical data for high-quality, boron-doped diamond thin-film electrodes are presented. Films from two different sources were compared (NRL and USU) and both were highly conductive, hydrogen-terminated, and polycrystalline. The films are acid washed and hydrogen plasma treated prior to use to remove nondiamond carbon impurity phases and to hydrogen terminate the surface. The boron-doping level of the NRL film was estimated to be in the mid 1019 B/cm3 range, and the boron-doping level of the USU films was approximately 5 x 10(20) B/cm(-3) based on boron nuclear reaction analysis. The electrochemical response was evaluated using Fe-(CN)6(3-/4-), Ru(NH3)6(3+/2+), IrCl6(2-/3-), methyl viologen, dopamine, ascorbic acid, Fe(3+/2+), and chlorpromazine. Comparisons are made between the apparent heterogeneous electron-transfer rate constants, k0(app), observed at these high-quality diamond films and the rate constants reported in the literature for freshly activated glassy carbon. Ru(NH3)6(3+/2+), IrCl6(2-/3-), methyl viologen, and chlorpromazine all involve electron transfer that is insensitive to the diamond surface microstructure and chemistry with k0(app) in the 10(-2)-10(-1) cm/s range. The rate constants are mainly influenced by the electronic properites of the films. Fe(CN)6(3-/4-) undergoes electron transfer that is extremely sensitive to the surface chemistry with k0(app) in the range of 10(-2)-10(-1) cm/s at the hydrogen-terminated surface. An oxygen surface termination severely inhibits the rate of electron transfer. Fe(3+/2+) undergoes slow electron transfer at the hydrogen-terminated surface with k0(app) near 10(-5) cm/s. The rate of electron transfer at sp2 carbon electrodes is known to be mediated by surface carbonyl functionalities; however, this inner-sphere, catalytic pathway is absent on diamond due to the hydrogen termination. Dopamine, like other catechol and catecholamines, undergoes sluggish electron transfer with k0(app) between 10(-4) and 10(-5) cm/s. Converting the surface to an oxygen termination has little effect on k0(app). The slow kinetics may be related to weak adsorption of these analytes on the diamond surface. Ascorbic acid oxidation is very sensitive to the surface termination with the most negative Ep(ox) observed at the hydrogen-terminated surface. An oxygen surface termination shifts Ep(ox) positive by some 250 mV or more. An interfacial energy diagram is proposed to explain the electron transfer whereby the midgap density of states results primarily from the boron doping level and the lattice hydrogen. The films were additionally characterized by scanning electron microscopy and micro-Raman imaging spectroscopy. The cyclic voltammetric and kinetic data presented can serve as a benchmark for research groups evaluating the electrochemical properties of semimetallic (i.e., conductive), hydrogen-terminated, polycrystalline diamond.
The deposition, characterization, and electrochemical responsiveness of boron-doped nanocrystalline diamond thin-film electrodes is reported. The films consist of clusters of diamond grains, ∼50-100 nm in diameter, and possess an rms surface roughness of 34 nm over a 5 × 5 µm 2 area. The individual and randomly ordered diamond grains are approximately 10-15 nm in diameter, as evidenced by TEM. The ∼4-µm-thick films were deposited by microwave-assisted chemical vapor deposition (CVD) using a CH 4 /H 2 /Ar source gas mixture (1%/5%/95%). Under these conditions, C 2 , rather than CH 3 • , appears to be the dominant nucleation and growth precursor. The nanocrystallinity is a result of a growth and nucleation mechanism discovered by Gruen, which involves the insertion of C 2 carbon dimer into C-H bonds on the growth surface (MRS Bull. 1998, 23, 32). The nanocrystalline morphology results from a high renucleation rate. However, unlike previously reported nanocrystalline diamond thin films that have electrical properties dominated by the high fraction of π-bonded carbon atoms in the grain boundaries, the present films are doped with boron, either using B 2 H 6 or a solid-state boron diffusion source, and the electrical properties appear to be dominated by the charge carriers in the diamond. The films were characterized by scanning-electron microscopy, atomic-force microscopy, transmission-electron microscopy, visible-Raman spectroscopy, X-ray diffraction, boron-nuclear-reaction analysis, and cyclic voltammetry, using Fe(CN) 6 3-/4-, Ru(NH 3 ) 6 3+/2+ , IrCl 6 2-/3-, methyl viologen, Fe 3+/2+ , and 4-tertbutylcatechol. Analytical application of this advanced carbon electrode material for the detection of trace metal ions is discussed.
The need to activate thermoplastic surfaces using robust and efficient methods has been driven by the fact that replication techniques can be used to produce microfluidic devices in a high production mode and at low cost, making polymer microfluidics invaluable for in vitro diagnostics, such as circulating tumor cell (CTC) analysis, where device disposability is critical to mitigate artifacts associated with sample carryover. Modifying the surface chemistry of thermoplastic devices through activation techniques can be used to increase the wettability of the surface or to produce functional scaffolds to allow for the covalent attachment of biologics, such as antibodies for CTC recognition. Extensive surface characterization tools were used to investigate UV activation of various surfaces to produce uniform and high surface coverage of functional groups, such as carboxylic acids in microchannels of different aspect ratios. We found that the efficiency of the UV activation process is highly dependent on the microchannel aspect ratio and the identity of the thermoplastic substrate. Colorimetric assays and fluorescence imaging of UV-activated microchannels following EDC/NHS coupling of Cy3-labeled oligonucleotides indicated that UV-activation of a PMMA microchannel with an aspect ratio of ∼3 was significantly less efficient toward the bottom of the channel compared to the upper sections. This effect was a consequence of the bulk polymer's damping of the modifying UV radiation due to absorption artifacts. In contrast, this effect was less pronounced for COC. Moreover, we observed that after thermal fusion bonding of the device's cover plate to the substrate, many of the generated functional groups buried into the bulk rendering them inaccessible. The propensity of this surface reorganization was found to be higher for PMMA compared to COC. As an example of the effects of material and microchannel aspect ratios on device functionality, thermoplastic devices for the selection of CTCs from whole blood were evaluated, which required the immobilization of monoclonal antibodies to channel walls. From our results, we concluded the CTC yield and purity of isolated CTCs were dependent on the substrate material with COC producing the highest clinical yields for CTCs as well as better purities compared to PMMA.
A circulating tumor cell (CTC) selection microfluidic device was integrated to an electrokinetic enrichment device for preconcentrating CTCs directly from whole blood to allow for the detection of mutations contained within the genomic DNA of the CTCs. Molecular profiling of CTCs can provide important clinical information that cannot be garnered simply by enumerating the selected CTCs. We evaluated our approach using SW620 and HT29 cells (colorectal cancer cell lines) seeded into whole blood as a model system. Because SW620 and HT29 cells overexpress the integral membrane protein EpCAM, they could be immunospecifically selected using a microfluidic device containing anti-EpCAM antibodies immobilized to the walls of a selection bed. The microfluidic device was operated at an optimized flow rate of 2 mm s−1, which allowed for the ability to process 1 mL of whole blood in <40 min. The selected CTCs were then enzymatically released from the antibody selection surface and hydrodynamically transported through a pair of Pt electrodes for conductivity-based enumeration. The efficiency of CTC selection was found to be 96% ± 4%. Following enumeration, the CTCs were hydrodynamically transported at a flow rate of 1 μL min−1 to an on-chip electromanipulation unit, where they were electrophoretically withdrawn from the bulk hydrodynamic flow and directed into a receiving reservoir. Using an electric field of 100 V cm−1, the negatively charged CTCs were enriched into an anodic receiving reservoir to a final volume of 2 μL, providing an enrichment factor of 500. The collected CTCs could then be searched for point mutations using a PCR/LDR/capillary electrophoresis assay. The DNA extracted from the CTCs was subjected to a primary polymerase chain reaction (PCR) with the amplicons used for a ligase detection reaction (LDR) to probe for KRAS oncogenic point mutations. Point mutations in codon 12 of the KRAS gene were successfully detected in the SW620 CTCs for samples containing <10 CTCs in 1 mL of whole blood. However, the HT29 cells did not contain these mutations, consistent with their known genotype.
We present a critical review of microfluidic technologies and material effects on the analyses of circulating tumour cells (CTCs) selected from the peripheral blood of cancer patients. CTCs are a minimally invasive source of clinical information that can be used to prognose patient outcome, monitor minimal residual disease, assess tumour resistance to therapeutic agents, and potentially screen individuals for the early diagnosis of cancer. The performance of CTC isolation technologies depends on microfluidic architectures, the underyling principles of isolation, and the choice of materials. In this review, we present a critical review of the fundamental principles used in these technologies and discuss their performance. We also give context to how CTC isolation technologies enable downstream analysis of selected CTCs in terms of detecting genetic mutations and gene expression that could be used to gain information that may affect patient outcome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.