This paper presents the results of an interlaboratory comparison of retrospective dosimetry using the electron paramagnetic resonance method. The test material used in this exercise was glass coming from the touch screens of smart phones that might be used as fortuitous dosimeters in a large-scale radiological incident. There were 13 participants to whom samples were dispatched, and 11 laboratories reported results. The participants received five calibration samples (0, 0.8, 2, 4, and 10 Gy) and four blindly irradiated samples (0, 0.9, 1.3, and 3.3 Gy). Participants were divided into two groups: for group A (formed by three participants), samples came from a homogeneous batch of glass and were stored in similar setting; for group B (formed by eight participants), samples came from different smart phones and stored in different settings of light and temperature. The calibration curves determined by the participants of group A had a small error and a critical level in the 0.37-0.40-Gy dose range, whereas the curves determined by the participants of group B were more scattered and led to a critical level in the 1.3-3.2-Gy dose range for six participants out of eight. Group A were able to assess the dose within 20 % for the lowest doses (<1.5 Gy) and within 5 % for the highest doses. For group B, only the highest blind dose could be evaluated in a reliable way because of the high critical values involved. The results from group A are encouraging, whereas the results from group B suggest that the influence of environmental conditions and the intervariability of samples coming from different smart phones need to be further investigated. An alongside conclusion is that the protocol was easily transferred to participants making a network of laboratories in case of a mass casualty event potentially feasible.
In this study, samples of smart phone touch screen glass sheets and tempered glass screen protectors were examined with respect to their potential application in the dosimetry of ionizing radiation. The glass samples were obtained from various phones with different types of glass. Electron paramagnetic resonance (EPR) spectra of the radiation-induced signals (RIS) are presented and their dose dependence within a dose range of 0–20 Gy. Despite the observed fading with time of the dosimetric components of the signal, the remaining RIS turned out to be strong enough for a reliable dosimetry even 18 month after irradiation. The study also shows that crushing of the glass sheets and water treatment of the samples have no effect on the background and dosimetric EPR signals.
In the present study, bone samples from three patients treated in radiotherapy facilities in Poland were used for the determination of doses absorbed during radiotherapy. The samples were obtained during surgical treatments of patients performed due to medical indications. For the purpose of retrospective dosimetry, sensitivity of the radiation-induced EPR signal was individually calibrated in the samples by re-irradiation of the samples with known doses. The doses reconstructed in bones extracted within 6 months after irradiation were consistent with those calculated by treatment planning systems. The dose reconstructed in the bone removed 6 y after radiotherapy was ∼14% lower than the calculated one.
The effects of illumination of nail clippings by direct sunlight, UV lamps and fluorescent bulbs on native and radiationinduced electron paramagnetic resonance (EPR) signals in nails are presented. It is shown that a few minutes of exposure of the nail clippings to light including a UV component (sunlight and UV lamps) generates a strong EPR signal similar to the other EPR signals observable in nails: native background (BKG), mechanically induced (MIS) or radiation-induced (RIS). This effect was observed in clippings exposed and unexposed to ionizing radiation prior to the light illuminations. An exposure of the clippings to fluorescent light without a UV component generated, within the examined range of the light fluences (up to 240 kJ/m 2), an EPR signal with considerably lower yield than UV light. The light-induced signal (LIS) decayed after 10 min of water treatment of the samples. In contrast, it was still observable 3 months after illumination in samples stored in air at room temperature, and 3 weeks in frozen samples, respectively. It is concluded that the LIS can considerably affect assessment of the dosimetric RIS components in irradiated nails, and of the background signals in unirradiated nails, thus contributing to errors in EPR dosimetry in nails.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.