Inert gas washout tests, performed using the single-or multiple-breath washout technique, were first described over 60 years ago. As measures of ventilation distribution inhomogeneity, they offer complementary information to standard lung function tests, such as spirometry, as well as improved feasibility across wider age ranges and improved sensitivity in the detection of early lung damage. These benefits have led to a resurgence of interest in these techniques from manufacturers, clinicians and researchers, yet detailed guidelines for washout equipment specifications, test performance and analysis are lacking. This manuscript provides recommendations about these aspects, applicable to both the paediatric and adult testing environment, whilst outlining the important principles that are essential for the reader to understand. These recommendations are evidence based, where possible, but in many places represent expert opinion from a working group with a large collective experience in the techniques discussed.Finally, the important issues that remain unanswered are highlighted. By addressing these important issues and directing future research, the hope is to facilitate the incorporation of these promising tests into routine clinical practice.
We have studied gas flow and particle deposition in a realistic three-dimensional (3D) model of the bronchial tree, extending from the trachea to the segmental bronchi (7th airway generation for the most distal ones) using computational fluid dynamics. The model is based on the morphometrical data of Horsfield et al. (Horsfield K, Dart G, Olson DE, Filley GF, and Cumming G. J Appl Physiol 31: 207-217, 1971) and on bronchoscopic and computerized tomography images, which give the spatial 3D orientation of the curved ducts. It incorporates realistic angles of successive branching planes. Steady inspiratory flow varying between 50 and 500 cm(3)/s was simulated, as well as deposition of spherical aerosol particles (1-7 microm diameter, 1 g/cm(3) density). Flow simulations indicated nonfully developed flows in the branches due to their relative short lengths. Velocity flow profiles in the segmental bronchi, taken one diameter downstream of the bifurcation, were distorted compared with the flow in a simple curved tube, and wide patterns of secondary flow fields were observed. Both were due to the asymmetrical 3D configuration of the bifurcating network. Viscous pressure drop in the model was compared with results obtained by Pedley et al. (Pedley TJ, Schroter RC, and Sudlow MF. Respir Physiol 9: 387-405, 1970), which are shown to be a good first approximation. Particle deposition increased with particle size and was minimal for approximately 200 cm(3)/s inspiratory flow, but it was highly heterogeneous for branches of the same generation.
We performed multiple-breath N2 washouts (MBNW) with tidal volumes of 1 liter at 8-16 breaths/min and constant flow rates in six normal subjects. For each breath we computed the slope of the alveolar plateau, normalized by the mean expired N2 concentration (Sn), the Bohr dead space (VDB), an index analogous to the Fowler dead space (V50), and the normalized slope of phase II (S2). In four subjects helium (He) and sulfur hexafluoride (SF6) were washed out after equilibration with a 5% gas mixture of each tracer. The Sn for He and SF6 increased in consecutive breaths, but the difference (delta Sn) increased only over the first five breaths, remaining constant thereafter. In all six subjects Sn, VDB, and V50 increased progressively in consecutive breaths of the MBNW, the increase in Sn being the greatest, approximately 290% from the first to the 23-25th breath. In contrast, S2 was unchanged initially and decreased after the sixth breath. The results indicate that after the fifth breath the increase in Sn during a MBNW is diffusion independent and may constitute a sensitive index of convection-dependent inhomogeneity (CDI). Subtraction of this component from the first breath suggests that Sn in a single-breath washout is largely due to a diffusion-dependent mechanism. The latter may reflect an interaction of convection and diffusion within the lung periphery, whereas CDI may comprise ventilation inequality among larger units, subtended by more centrally located branch points.
We investigated ventilation inhomogeneity during provocation with inhaled histamine in 20 asymptomatic nonsmoking subjects. We used N2 multiple-breath washout (MBW) to derive parameters Scond and Sacin as a measurement of ventilation inhomogeneity in conductive and acinar zones of the lungs, respectively. A 20% decrease of forced expiratory volume in 1 s (FEV1) was used to distinguish responders from nonresponders. In the responder group, average FEV1 decreased by 26%, whereas Scond increased by 390% with no significant change in Sacin. In the nonresponder group, FEV1 decreased by 11%, whereas Scond increased by 198% with no significant Sacin change. Despite the absence of change in Sacin during provocation, baseline Sacin was significantly larger in the responder vs. the nonresponder group. The main findings of our study are that during provocation large ventilation inhomogeneities occur, that the small airways affected by the provocation process are situated proximal to the acinar zone where the diffusion front stands, and that, in addition to overall decrease in airway caliber, there is inhomogeneous narrowing of parallel airways.
This outbreak was unique, because it affected a large, urban, predominantly young, middle-class, otherwise healthy population and resulted in an unprecedented public health emergency. Rapid diagnosis and treatment avoided higher lethality. Food-borne transmission of T. cruzi may occur more often than is currently recognized.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.