Objective: Total knee arthroplasty (TKA) is one of the most universal and effective means for treating terminal stage osteoarthritis (OA) of knee. Accurate intramedullary guide of femur is the basis for the distal femoral cuts. Determining the surgical transepicondylar axis (sTEA) is the key to reconstruction of the femoral rotational alignment, because the correct rotational alignment can place the femoral component in the right position, balance the flexion gap so that the inner and outer tension is equal, get stability during the flexion process of the knee, and enhance the quality of life of patients. With the development of three-dimensional printing (3DP) technology in the medical domain, the application of patient-specific instrumentation (PSI) in arthroplasty has become more common. The aim of this study was to evaluate the accuracy of a novel 3D-printed patient-specific intramedullary guide to control femoral component rotation in TKA.Methods: Eighty patients (65 females and 15 males) with knee OA were included in this prospective randomized study. The patients were divided into two groups by random number table method, 40 in each group. TKA assisted by PSI (PSI group) and conventional TKA (conventional group) was performed respectively. Clinical outcomes [operation time, postoperative drainage volume, duration of drainage, Hospital for Special Surgery knee score (HSS), American Knee Society knee score (AKS)] and radiological outcomes [hip-knee-ankle angle (HKA), posterior condylar angle (PCA), patella transverse axis-femoral transepicondylar axis angle (PFA), depth of intramedullary guide] were compared between and within the two groups.Results: PSI group had less postoperative drainage volume but longer operation time than the conventional group (P < 0.05). The AKS and HSS scores after surgery were improved compared with those before surgery in each group (P < 0.05). However, there was no significant difference in the duration of drainage and range of motion (ROM) after surgery between the two groups. For the radiological results, the HKA and PFA were improved after surgery in both groups (P < 0.05).The postoperative PFA and PCA of the PSI group were closer to 0 , which was better than that of the conventional group (P < 0.05). The depth of intramedullary guide in the PSI group was less than the conventional group (P < 0.05). But there was no significant difference in HKA before and after surgery between the two groups as well as the preoperative PFA.
Conclusion:The short-term clinical efficacy of TKA assisted by PSI was similar to the conventional TKA. Although TKA assisted by PSI spent more time during operation, it could assist in intramedullary guide and align femoral rotation more accurately.
Background. With the development of three-dimensional printing (3DP) technology, the patient-specific instrumentation (PSI) has been widely applied in total knee arthroplasty (TKA). The purpose of this study was to compare the gait parameters of patients with 3DP personalized guide-assisted and standard TKA. Methods. Retrospective analysis of the advanced knee OA cases in our hospital between June 2017 and June 2018 was conducted. 30 cases received 3DP personalized guide-assisted TKA (group A), and 60 patients who underwent standard TKA during the same period were in group B and group C according to the computed tomography (CT) measurement results, each with 30 cases. Hip–knee–ankle angle (HKA), patella transverse axis-femoral transepicondylar axis angle (PFA), and gait parameters were statistically analyzed. The function was assessed by Hospital for Specific Surgery (HSS) and Knee Society Score (KSS). Results. The mean follow-up period was 12.3 months in the three groups. The knee max flexion angle at the swing phase of group A was larger than group B and group C (P<0.05), there was no statistically significant difference in other gait parameters. The mean PFA of group A was smaller than that of group B and group C (P<0.05). While, the HKA, HSS, and KSS scores of three groups showed no significant difference. Conclusion. 3DP personalized guide technology could improve the gait parameters after surgery, specifically reflected in the knee max flexion angle at the swing phase. It could also assist in the reconstruction of more accurate patellar tracking and rotational alignment in TKA, avoiding the occurrence of insufficient or excessive extorsion.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.