[1] The Arctic polar vortex exhibited widespread regions of low temperatures during the winter of 2005, resulting in significant ozone depletion by chlorine and bromine species. We show that chemical loss of column ozone (DO 3 ) and the volume of Arctic vortex air cold enough to support the existence of polar stratospheric clouds (V PSC ) both exceed levels found for any other Arctic winter during the past 40 years. Cold conditions and ozone loss in the lowermost Arctic stratosphere (e.g., between potential temperatures of 360 to 400 K) were particularly unusual compared to previous years. Measurements indicate DO 3 = 121 ± 20 DU and that DO 3 versus V PSC lies along an extension of the compact, near linear relation observed for previous Arctic winters. The maximum value of V PSC during five to ten year intervals exhibits a steady, monotonic increase over the past four decades, indicating that the coldest Arctic winters have become significantly colder, and hence are more conducive to ozone depletion by anthropogenic halogens.
[1] We present validation studies of MLS version 2.2 upper tropospheric and stratospheric ozone profiles using ozonesonde and lidar data as well as climatological data. Ozone measurements from over 60 ozonesonde stations worldwide and three lidar stations are compared with coincident MLS data. The MLS ozone stratospheric data between 150 and 3 hPa agree well with ozonesonde measurements, within 8% for the global average. MLS values at 215 hPa are biased high compared to ozonesondes by $20% at middle to high latitude, although there is a lot of variability in this altitude region. Comparisons between MLS and ground-based lidar measurements from Mauna Loa, Hawaii, from the Table Mountain Facility, California, and from the Observatoire de HauteProvence, France, give very good agreement, within $5%, for the stratospheric values. The comparisons between MLS and the Table Mountain Facility tropospheric ozone lidar show that MLS data are biased high by $30% at 215 hPa, consistent with that indicated by the ozonesonde data. We obtain better global average agreement between MLS and ozonesonde partial column values down to 215 hPa, although the average MLS values at low to middle latitudes are higher than the ozonesonde values by up to a few percent. MLS
Published by Copernicus Publications on behalf of the European Geosciences Union. 458 A. J. M. Piters et al.: The CINDI campaign: design, execution and early resultsAbstract. From June to July 2009 more than thirty different in-situ and remote sensing instruments from all over the world participated in the Cabauw Intercomparison campaign for Nitrogen Dioxide measuring Instruments (CINDI). The campaign took place at KNMI's Cabauw Experimental Site for Atmospheric Research (CESAR) in the Netherlands. Its main objectives were to determine the accuracy of state-ofthe-art ground-based measurement techniques for the detection of atmospheric nitrogen dioxide (both in-situ and remote sensing), and to investigate their usability in satellite data validation. The expected outcomes are recommendations regarding the operation and calibration of such instruments, retrieval settings, and observation strategies for the use in ground-based networks for air quality monitoring and satellite data validation. Twenty-four optical spectrometers participated in the campaign, of which twenty-one had the capability to scan different elevation angles consecutively, the so-called Multi-axis DOAS systems, thereby collecting vertical profile information, in particular for nitrogen dioxide and aerosol. Various in-situ samplers and lidar instruments simultaneously characterized the variability of atmospheric trace gases and the physical properties of aerosol particles. A large data set of continuous measurements of these atmospheric constituents has been collected under various meteorological conditions and air pollution levels. Together with the permanent measurement capability at the CE-SAR site characterizing the meteorological state of the atmosphere, the CINDI campaign provided a comprehensive observational data set of atmospheric constituents in a highly polluted region of the world during summertime. First detailed comparisons performed with the CINDI data show that slant column measurements of NO 2 , O 4 and HCHO with MAX-DOAS agree within 5 to 15 %, vertical profiles of NO 2 derived from several independent instruments agree within 25 % of one another, and MAX-DOAS aerosol optical thickness agrees within 20-30 % with AERONET data. For the in-situ NO 2 instrument using a molybdenum converter, a bias was found as large as 5 ppbv during day time, when compared to the other in-situ instruments using photolytic converters.
In March 2002 the European Space Agency (ESA) launched the polar‐orbiting environmental satellite Envisat. One of its nine instruments is the Global Ozone Monitoring by Occultation of Stars (GOMOS) instrument, which is a medium‐resolution stellar occultation spectrometer measuring vertical profiles of ozone. In the first year after launch a large group of scientists performed additional measurements and validation activities to assess the quality of Envisat observations. In this paper, we present validation results of GOMOS ozone profiles from comparisons to microwave radiometer, balloon ozonesonde, and lidar measurements worldwide. Thirty‐one instruments/launch sites at twenty‐five stations ranging from the Arctic to the Antarctic joined in this activity. We identified 6747 collocated observations that were performed within an 800‐km radius and a maximum 20‐hour time difference of a satellite observation, for the period between 1 July 2002 and 1 April 2003. The GOMOS data analyzed here have been generated with a prototype processor that corresponds to version 4.02 of the operational GOMOS processor. The GOMOS data initially contained many obviously unrealistic values, most of which were successfully removed by imposing data quality criteria. Analyzing the effect of these criteria indicated, among other things, that for some specific stars, only less than 10% of their occultations yield an acceptable profile. The total number of useful collocated observations was reduced to 2502 because of GOMOS data unavailability, the imposed data quality criteria, and lack of altitude overlap. These collocated profiles were compared, and the results were analyzed for possible dependencies on several geophysical (e.g., latitude) and GOMOS observational (e.g., star characteristics) parameters. We find that GOMOS data quality is strongly dependent on the illumination of the limb through which the star is observed. Data measured under bright limb conditions, and to a certain extent also in twilight limb, should be used with caution, as their usability is doubtful. In dark limb the GOMOS data agree very well with the correlative data, and between 14‐ and 64‐km altitude their differences only show a small (2.5–7.5%) insignificant negative bias with a standard deviation of 11–16% (19–63 km). This conclusion was demonstrated to be independent of the star temperature and magnitude and the latitudinal region of the GOMOS observation, with the exception of a slightly larger bias in the polar regions at altitudes between 35 and 45 km.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.