A fast and direct determination procedure for precious metals in spent automotive catalyst was developed using the novel high-energy polarized-beam XRF. A sample preparation method working directly on the ground material was optimized. The material was pressed as a pellet using wax as a binder; no internal standard was added. The standards for this application were available spent automotive catalyst, previously analyzed by ICP-OES to verify their concentration, prepared in the same way as the unknown samples. The investigated concentration ranged from nearly 0 to approximately 2700 ppm for Pt, to 500 ppm for Rh, and to 7500 ppm for Pd. The repeatability of the XRF measurement appeared to be better than 0.5%, while the precision of the whole method was approximately 1%. The accuracy of the XRF method was verified with the well-established (but very time-consuming) ICP-OES method; a good agreement (no difference when using the 95% confidence interval) was found for the results. When using an irradiation time of 500 s for the CsI secondary target and the Zr secondary target, the detection limits for Pt, Pd, and Rh were found to be better than 5 ppm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.