The aim of this study was to compare MR imaging and endoscopic ultrasonography (EUS) for the local staging of rectal tumours. Forty-nine patients were examined on a 1.5-T MR unit using either a pelvic phased-array coil (n = 37) alone or combined with an endorectal coil (n = 12). Sagittal and axial sequences with T2-weighted fast spin-echo and axial T1-weighted spin-echo techniques were employed. The EUS technique was performed using a flexible endosonoscope. The results were compared with findings at histopathological sectioning of the specimen. The T-stage on MR correlated with histopathology in 32 of 49 patients and on EUS in 29 of 49 patients. The N-stage on MR correlated with histopathology in 22 of 49 patients and on EUS in 26 of 49 patients. Tumour penetration of the rectal wall was predicted by MR with 86 % sensitivity and 65 % specificity, and by EUS with 89% sensitivity and 33% specificity. Preoperative radiotherapy was administered to 40 of the patients after the examinations which may explain some of the overstaging by MR and EUS. Three patients with surgically and histopathologically confirmed invasion of neighbouring organs in the pelvis were detected preoperatively on MR but none on EUS. Tumour penetration of the rectal wall and local lymph node metastases cannot accurately be predicted with MR or EUS. Magnetic resonance, however, seems to be more useful for preoperative identification of clinically occult advanced disease.
Lack of resolution of hyperparathyroidism after long-term renal transplantation is common. The relative roles of the graft function attained and the degree of pre-transplant hyperparathyroidism have not been established. Intact parathyroid hormone (iPTH) and several clinical parameters were studied before and 68.6+/-26.8 months (range: 30-124) after renal transplantation in 62 patients (20 females/42 males) with good renal function (creatinine <2 mg/dl). iPTH decreased from 214+/-229 pre-transplantation to 116+/-70 pg/ml post-transplantation (P<0.01). However, only 22.6% of patients had PTH concentrations in the normal range, and values greater than twice the upper normal limit were not uncommon (27.4%). Of the many variables analysed, creatinine (r=0.43; P=0.001) and pre-transplant PTH (r=0.31; P=0.02) significantly correlated with post-transplant PTH. After selecting patients with serum creatinine <1.5 mg/dl (n=46), pre-transplant PTH emerged as the more important predictor of post-transplant PTH (r=0.58; P<0.0001). After controlling for creatinine, the partial correlation was r=0.53, P<0.0001. We concluded that spontaneous resolution of hyperparathyroidism after renal transplantation is uncommon. In addition, the magnitude of pre-transplant hyperparathyroidism and the renal function determine the long-term post-transplant parathyroid function.
The aim of the present study was to investigate whether MRI could predict tumour involvement of the lateral resection margin on resected rectal cancer specimens. 26 specimens obtained after total mesorectal excision were examined in the sagittal and axial plane on a clinical 1.5 T MR system using phased-array surface coils. The shortest distance between the deepest point of tumour penetration and the lateral resection margin was measured. This distance is referred to as LRM. The results were correlated to measurements on digital images of giant histopathological sections. The total number of lymph nodes and lymph node metastases was also counted. LRM was less than or equal to 1 mm (a distance considered for non-radically excised tumours) in eight of the histopathological specimens. On MR images of the resected specimen, LRM was less than or equal to 1 mm in seven of these specimens. LRM was shorter in MR examinations than in histopathological giant sections in 11 specimens. The sensitivity, specificity, positive and negative predictive values for prediction of tumour involvement of the lateral resection margin (LRM < or = 1 mm) by MR of the resected specimen were 88%, 78%, 64% and 93%, respectively. Presence of lymph node metastases could not accurately be predicted by MR. However, it is concluded that the presence of a tumour free lateral resection margin can be predicted by MRI of resected rectal specimens when this exceeds 1 mm.
We report on a case of right adrenal pheochromocytoma with extension to the supra-diaphragmatic vena cava, which underwent surgical excision through thoracophrenic laparotomy without the need for cardiopulmonary bypass. In a 6-year follow-up, another pheochromocytoma was found in the infra-renal Zuckerkandl's organ. Complete surgical excision of the tumor was performed by a median laparotomy and complete retroperitoneal dissection. In both cases, the total removal of the pheochromocytoma has been guaranteed by having margins free of tumor and a normal post-operative level of catecholamines. The pathological study revealed a malignant pheochromocytoma with margins free of neoplasia in both specimens.
Brazil. Critical revision, design and supervise all phases of the study. ABSTRACT PURPOSE:To quantify the amount of lymph nodes harvested in modified radical neck dissection. METHODS:Cross-sectional anatomical study conducted in 28 non-preserved cadavers. RESULTS:The mean number of lymph nodes found in each nodal level of the 56 modified radical neck dissections performed were:level IA -1.5 (95% CI: 1.1 -1.8), level IB -2.5 (95% CI: 2.1 -2.9), level IIA -7.2 (95% CI: 6.0 -8.5), IIB level -6.5 (95% CI: 5.5 -7.4), level III -6.6 (95% CI: 5.7 -7.4), level IV -8.6 (95% CI: 7.1 -10.1), level V -11 (95% CI: 9.2 -12.7), totalizing 43.8 lymph nodes (95% CI: 40.3 -47.4). CONCLUSION:The results defined a parameter in relation to the minimum recommended nodal yield in a modified radical neck dissection, as well as the number of lymph nodes in each level of this dissection, performed in clinical practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.