This paper presents a novel seven-rod sensor used for time-domain reflectometry (TDR) and frequency-domain reflectometry (FDR) measurements of soil water content in a well-defined sample volume. The probe directly measures the complex dielectric permittivity spectrum and for this purpose requires three calibration media: air, water, and ethanol. Firstly, electromagnetic simulations were used to study the influence of the diameter of a container on the sensitivity zone of the probe with respect to the measured calibration media and isopropanol as a verification liquid. Next, the probe was tested in three soils—sandy loam and two silt loams—with six water contents from air-dry to saturation. The conversion from S 11 parameters to complex dielectric permittivity from vector network analyzer (VNA) measurements was obtained using an open-ended liquid procedure. The simulation and measurement results for the real part of the isopropanol dielectric permittivity obtained from four containers with different diameters were in good agreement with literature data up to 200 MHz. The real part of the dielectric permittivity was extracted and related to the moisture of the tested soil samples. Relations between the volumetric water content and the real part of the dielectric permittivity (by FDR) and apparent dielectric permittivity (by TDR) were compared with Topp’s equation. It was concluded that the best fit to Topp’s equation was observed in the case of a sandy loam. Data calculated according to the equation proposed by Malicki, Plagge, and Roth gave results closer to Topp’s calibration. The obtained results indicated that the seven-rod probe can be used to accurately measure of the dielectric permittivity spectrum in a well-defined sample volume of about 8 cm3 in the frequency range from 20 MHz to 200 MHz.
Time-domain reflectometry (TDR) methods used for measuring the dielectric properties of materials mostly utilize step or needle electrical pulses of constant amplitudes and shapes. Our novel approach enables determining the dielectric relaxation time of a sample using the analysis of the amplitudes of reflected pulses of two widths, in addition to bulk dielectric permittivity and electrical conductivity commonly obtained by the TDR technique. The method was developed for various values of electrical conductivity and relaxation time using numerical simulations of a five-rod probe placed in a material with complex dielectric permittivity described by the Debye model with an added electrical conductivity term. The characterization of amplitudes of two pulses of selected widths was done with regard to the dielectric parameters of simulated materials. The required probe parameters were obtained solely from numerical simulations. Verification was performed for the probe placed in aqueous KCl solutions with 14 different electrical conductivity values. The determined relaxation time remained roughly constant and independent of electrical conductivity. The obtained electrical conductivity agreed with the reference values. Our results indicate that the relaxation time, dielectric permittivity and electrical conductivity of the tested solutions can be simultaneously determined using a simple analysis of the amplitude and reflection time of two needle pulses of different widths.
This paper presents dielectric measurements of talc, glass beads, and their mixtures under different moisture and salinity levels. The measurements were conducted using a prototype seven-rod probe (15 mm long central rod) connected to a single port of vector network analyzer. The samples were moistened with distilled water and KCl solutions in order to obtain six different moisture content levels. The complex dielectric permittivity was determined from vector network analyzer reflection-coefficient measurements based on the open-water-liquid calibration procedure. Next, the fitting of volumetric water content–real part of dielectric permittivity calibration curves was performed for each material at selected frequencies, and the obtained relations were compared with well-known calibration equations. Additionally, a salinity index for the tested materials was calculated. It was concluded that pure talc is not an optimal material for the calibration and verification of dielectric methods. The calibration curves obtained for glass beads and the mixtures of glass beads with talc gave results close to well-known reference calibration functions. Additionally, the addition of talc caused the data points to be less scattered. Moreover, the values of the salinity index for the tested materials were in a good agreement with literature data for sand. The obtained results indicated that glass beads with the addition of talc can be used as a reference material for the calibration and verification of dielectric methods and devices for soil moisture measurement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.