Prepulse inhibition (PPI) test has been widely used to evaluate sensorimotor gating. In humans, deficits in this mechanism are measured through the orbicularis muscle response using electromyography (EMG). Although this mechanism can be modulated by several brain structures and is impaired in some pathologies as schizophrenia and bipolar disorder, neural PPI evaluation is rarely performed in humans. Since eye blinks are a consequence of PPI stimulation, they strongly contaminate the electroencephalogram (EEG) signal. This paper describes a method to reduce muscular artifacts and enable neural PPI assessment through EEG in parallel to muscular PPI evaluation using EMG. Both types of signal were simultaneously recorded in 22 healthy subjects. PPI was evaluated by the acoustical startle response with EMG and by the P2-N1 event-related potential (ERP) using EEG in Fz, Cz, and Pz electrodes. In order to remove EEG artifacts, Independent Component Analysis (ICA) was performed using two methods. Firstly, visual inspection discarded components containing artifact characteristics as ocular and tonic muscle artifacts. The second method used visual inspection as gold standard to validate parameters in an automated component selection using the SASICA algorithm. As an outcome, EEG artifacts were effectively removed and equivalent neural PPI evaluation performance was obtained using both methods, with subjects exhibiting consistent neural as well as muscular PPI. This novel method improves PPI test, enabling neural gating mechanisms assessment within the latency of 100–200 ms, which is not evaluated by other sensory gating tests as P50 and mismatch negativity.
Background: Altered sensorimotor gating has been demonstrated by Prepulse Inhibition (PPI) tests in patients with psychosis. Recent advances in signal processing methods allow assessment of neural PPI through electroencephalogram (EEG) recording during acoustic startle response measures (classic muscular PPI). Simultaneous measurements of muscular (eye-blink) and neural gating phenomena during PPI test may help to better understand sensorial processing dysfunctions in psychosis. In this study, we aimed to assess simultaneously muscular and neural PPI in early bipolar disorder and schizophrenia patients. Method: Participants were recruited from a population-based case-control study of first episode psychosis. PPI was measured using electromyography (EMG) and EEG in pulse alone and prepulse + pulse with intervals of 30, 60, and 120 ms in early bipolar disorder (n = 18) and schizophrenia (n = 11) patients. As control group, 15 socio-economically matched healthy subjects were recruited. All subjects were evaluated with Rating Scale, Hamilton Rating Scale for Depression, and Young Mania Rating Scale questionnaires at recruitment and just before PPI test. Wilcoxon ranked sum tests were used to compare PPI test results between groups. Results: In comparison to healthy participants, neural PPI was significantly reduced in PPI 30 and PPI60 among bipolar and schizophrenia patients, while muscular PPI was reduced in PPI60 and PPI120 intervals only among patients with schizophrenia. Conclusion: The combination of muscular and neural PPI evaluations suggested distinct impairment patterns among schizophrenia and bipolar disorder patients. Simultaneous recording may contribute with novel information in sensory gating investigations.
Prepulse inhibition (PPI) consists of a reduction of the acoustic startle reflex (SR) magnitude (measured with EMG) when a startling stimulus is preceded by a non-startling one. This behavior has been extensively investigated in studies related to schizophrenia, since sensory-motor deficit plays a central role in its pathophysiology. However, the same auditory stimuli that trigger the SR also provoke intense auditory evoked responses (AEP), which can be measured with EEG. Comparing these two types of responses, acquired simultaneously, is a great opportunity to investigate the dependence and interdependence of their neural pathways. Nonetheless, so far very few studies have dared to perform such simultaneous recordings, because SR produces strong eye blinks and muscle contraction artifacts that contaminate EEG electrodes placed on the scalp. In this study we investigated the possibility of simultaneously obtaining both the acoustic SR (using EMG) and the AEP (using EEG) measures, through the use of advanced artifact removal techniques, to better characterize PPI in healthy humans.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.