Since students and teachers spend much of their time in educational buildings, it is critical to provide good levels of indoor environmental quality (IEQ). The current COVID-19 pandemic has shown that maintaining a good indoor air quality level is an effective measure to control the transmission of the SARS-CoV-2 virus. This study used sensors to monitor key IEQ factors and assess several natural ventilation scenarios in a classroom of the University of Granada. Subsequently, the IEQ factors (temperature, relative humidity, CO2 concentration, acoustic environment, and air velocity) were evaluated for the selected ventilation scenarios in the occupied classroom, and the field monitoring was carried out in two different assessment periods, winter and summer. The obtained results show that the CO2 concentration levels were well below the recommended limits. However, the maintenance of the recommended thermal and acoustic IEQ factors was significantly affected by the natural ventilation strategies (temperature and relative humidity values were very close to the outside values, and the background sound pressure level was over 35 dBA during the entire assessment). The proper measurements and careful selection of the appropriate ventilation scenarios become of utmost importance to ensure that the ventilation rates required by the health authorities are achieved.
Indoor environmental conditions can significantly affect occupants’ health and comfort. These conditions are especially important in educational buildings, where students, teachers and staff spend long periods of the day and are vulnerable to these factors. Recently, indoor air quality has been a focus of attention to ensure that disease transmission in these spaces is minimised. In order to increase the knowledge in this field, experimental tests have been carried out to characterise the impact of natural ventilation strategies on indoor air quality and the acoustic environment. This study has evaluated three ventilation scenarios in four different classrooms in buildings of the University of Granada, considering different window and door opening configurations. Ventilation rates were estimated using the CO2 Decay Method, and background noise recordings were made in each classroom for acoustic tests. Results show that specific natural ventilation strategies have a relevant impact that is worth considering on the background noise in indoor spaces. In this sense ventilation rates provided by the different configurations varied between 3.7 and 39.8 air changes per hour (ACH) and the acoustic tests show a background noise ranging from 43 to 54 dBA in these scenarios. Consequently, managers and teachers should take into account not only the ACH, but also other collateral impacts on the indoor environmental conditions such as the thermal comfort or the acoustic environment.
The indoor thermal environment has become a critical factor, due to its impact on the energy efficiency of a building and the health and performance of its occupants. It is particularly important for educational buildings, where students and teachers are exposed to these thermal conditions. This study assessed the impact of natural ventilation efficiency and university students’ thermal perception during the cold season. A field monitoring campaign and a questionnaire survey were conducted. A total of 989 students participated in this study. The results show that, although the CO2 concentration in 90% of the evaluated classrooms was below the European recommended value (i.e., 800 ppm), only 18% of the classrooms were within the thermal comfort zone defined by national regulations. These thermal conditions caused 55% of the students surveyed to report that they were dissatisfied, and that this environment interfered with their academic performance. Significant differences were found between thermal sensation votes from female and male students (p < 0.001). The obtained neutral temperature was one degree higher for female students than for males. Our results suggest that ventilation protocols need to be modified by adjusting the window opening strategy, and these findings should be used as guidelines during their redesign.
Managing indoor environmental quality (IEQ) is a challenge in educational buildings in the wake of the COVID-19 pandemic. Adequate indoor air quality is essential to ensure that indoor spaces are safe for students and teachers. In fact, poor IEQ can affect academic performance and student comfort. This study proposes a framework for integrating occupants’ feedback into the building information modelling (BIM) methodology to assess indoor environmental conditions (thermal, acoustic and lighting) and the individual airborne virus transmission risk during teaching activities. The information contained in the parametric 3D BIM model and the algorithmic environment of Dynamo were used to develop the framework. The IEQ evaluation is based on sensor monitoring and a daily schedule, so the results show real problems of occupants’ dissatisfaction. The output of the framework shows in which range the indoor environmental variables were (optimal, acceptable and unacceptable) and the probability of infection during each lecture class (whether or not 1% is exceeded). A case study was proposed to illustrate its application and validate it. The outcomes provide key information to support the decision-making process for managing IEQ and controlling individual airborne virus transmission risks. Long-term application could provide data that support the management of ventilation strategies and protocol redesign.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.