Plasma iron concentration alone is an accurate marker of SI in hospitalized horses. Alteration of both plasma iron and fibrinogen concentrations improves the specificity and positive predictive value for diagnosis of SI. Alteration of either one of both increases sensitivity and negative predictive value. Surviving horses normalized plasma iron concentrations during follow-up period. The combination of plasma iron and fibrinogen concentrations may help in the detection of SI. Follow-up of plasma iron concentrations may provide useful prognostic information.
This is an open access article under the terms of the Creat ive Commo ns Attri butio n-NonCo mmerc ial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
At the low end of the recommended dose in people this oral formulation of DiXaI did not reach prophylactic plasma antifactor Xa activity in this group of healthy adult horses. Further studies are warranted in order to establish the prophylactic dose for horses.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.