Single photon emission computed tomography (SPECT) imaging is widely implemented in nuclear medicine as its clinical role in the diagnosis and management of several diseases is, many times, very helpful (e.g., myocardium perfusion imaging). The quality of SPECT images are degraded by several factors such as noise because of the limited number of counts, attenuation, or scatter of photons. Image filtering is necessary to compensate these effects and, therefore, to improve image quality. The goal of filtering in tomographic images is to suppress statistical noise and simultaneously to preserve spatial resolution and contrast. The aim of this work is to describe the most widely used filters in SPECT applications and how these affect the image quality. The choice of the filter type, the cut-off frequency and the order is a major problem in clinical routine. In many clinical cases, information for specific parameters is not provided, and findings cannot be extrapolated to other similar SPECT imaging applications. A literature review for the determination of the mostly used filters in cardiac, brain, bone, liver, kidneys, and thyroid applications is also presented. As resulting from the overview, no filter is perfect, and the selection of the proper filters, most of the times, is done empirically. The standardization of image-processing results may limit the filter types for each SPECT examination to certain few filters and some of their parameters. Standardization, also, helps in reducing image processing time, as the filters and their parameters must be standardised before being put to clinical use. Commercial reconstruction software selections lead to comparable results interdepartmentally. The manufacturers normally supply default filters/parameters, but these may not be relevant in various clinical situations. After proper standardisation, it is possible to use many suitable filters or one optimal filter.
In unresectable metastatic liver lesions positive for somatostatin receptors repeated, transhepatic high doses of (111)In-DTPA-Phe(1)-octreotide show an effective therapeutic outcome. Given the locoregional modality character of the administration technique plus the extremely short range of (111)In Auger and internal conversion electrons emission, no nephro-, liver- or myelo-toxicity has so far been observed.
Rhenium-188 (Re-188) is a high energy β-emitting radioisotope obtained from the tungsten-188/rhenium-188 (W-188/Re-188) generator, which has shown utility for a variety of therapeutic applications in nuclear medicine, oncology, and interventional radiology/cardiology. Re-188 decay is accompanied by a 155 keV predominant energy γ-emission, which could be detected by γ-cameras, for imaging, biodistribution, or absorbed radiation dose studies. Its attractive physical properties and its potential low cost associated with a long-lived parent make it an interesting option for clinical use. The setup and daily use of W-188/Re-188 generator in hospital nuclear medicine departments are discussed in detail. The clinical efficacy, for several therapeutic applications, of a variety of Re-188-labeled agents is demonstrated. The high energy of the β-emission of Re-188 is particularly well suited for effective penetration in solid tumours. Its total radiation dose delivered to tissues is comparable to other radionuclides used in therapy. Furthermore, radiation safety and shielding requirements are an important subject of matter. In the case of bone metastases treatment, therapeutic ratios are presented in order to describe the efficacy of Re-188 usage.
The accuracy of MLC positions during radiotherapy is important as even small positional deviations can translate into considerable dose delivery errors. This becomes crucial when radiosensitive organs are located near the treated volume and especially during IMRT, where dose gradients are steep. A test commonly conducted to measure the positional accuracy of the MLCs is the Picket Fence test. In this study two alterations of the Picket Fence test were performed and evaluated, the first one using radiochromic EBT2 films and the second one the Delta4PT diode array phantom and its software. Our results showed that EBT2 films provide a relatively fast, qualitative visual inspection of the significant leaf dispositions. When slight inaccuracies need to be revealed or precise numerical results for each leaf position are needed, Delta4PT provides the desired accuracy of 1 mm. In treatment modalities where a higher accuracy is required in the delivered dose distribution, such as in IMRT, precise numerical values of the measurements for the MLC positional inspection are required.PACS number: 87.55.Qr, 87.56.bd, 87.56.Fc, 87.56.nk
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.