Objective: To identify risk factors for permanent and transient congenital hypothyroidism (CH). Design: A population-based case-control study was carried out by using the network created in Italy for the National Register of Infants with CH. Methods: Four controls were enrolled for each new CH infant; 173 cases and 690 controls were enrolled in 4 years. In order to distinguish among risk factors for permanent and transient CH, diagnosis was re-evaluated 3 years after enrolment when there was a suspicion of transient CH being present. Familial, maternal, neonatal and environmental influences were investigated. Results: An increased risk for permanent CH was detected in twins by a multivariate analysis (odds ratio (OR) ¼ 12.2, 95% confidence interval (CI): 2.4 -62.3). A statistically significant association with additional birth defects, female gender and gestational age .40 weeks was also confirmed. Although not significant, an increased risk of CH was observed among infants with a family history of thyroid diseases among parents (OR ¼ 1.9, 95% CI: 0.7-5.2). Maternal diabetes was also found to be slightly associated with permanent CH (OR ¼ 15.7, 95% CI: 0.9-523) in infants who were large for gestational age. With regard to transient CH, intrauterine growth retardation and preterm delivery were independent risk factors for this form of CH. Conclusion: This study showed that many risk factors contribute to the aetiology of CH. In particular, our results suggested a multifactorial origin of CH in which genetic and environmental factors play a role in the development of the disease. 153 765-773 European Journal of Endocrinology
Treatment with β-blockers is the main strategy for managing patients with heart failure and reduced ejection fraction because of their ability to reverse the neurohumoral effects of the sympathetic nervous system, with consequent prognostic and symptomatic benefits. However, to date, they are underused, mainly because of the misconception that hypotension and bradycardia may worsen the haemodynamic status of patients with HFrEF and because of the presence of comorbidities falsely believed to be absolute contraindications to their use. To promote proper use of β-blockers in this article, we review the clinical pharmacology of β-blockers, the evidence of the beneficial effects of these drugs in heart failure with reduced ejection fraction, and the current guidelines for their use in clinical practice and in the presence of comorbidities (e.g., pulmonary disease, diabetes, atrial fibrillation, peripheral arterial disease, etc.). It is hoped that the practical approach discussed in this review will allow for a proper diffusion of knowledge about the correct use of β-blockers and the drug-disease interactions to achieve their increased use and titration, as well as for the selection of a specific agent with a view to a properly tailored approach for HFrEF patients.
Objectives: the different analytical methods for measurement of serum 25-hydroxyvitamin D (25(OH)D) are not yet fully harmonized and no consensus exists on a threshold of 25(OH)D defining a deficiency status. In this study, we compared the results from the assays of serum 25(OH)D performed with three different methods to evaluate the presence of potential biases and how much these biases can influence the assignment of patients to specific 25(OH)D deficiency/sufficiency categories. Design and Methods: Liaison 25(OH) Vitamin D Total (DiaSorin Liaison XL), Elecsys Vitamin D Total II (Roche Elecsys) and Lumipulse G25(OH) Vitamin D (Fujirebio Lumipulse G1200) were used. Methods comparability was established performing Passing-Bablok regression and Bland-Altman analysis to prove whether the differences found were lower than the preliminarily pre-established maximum acceptable bias. Results: all Passing-Bablok regressions exhibited the presence of a proportional and constant systematic error. Bland-Altman analysis revealed biases well above the maximum acceptable bias, so the 25(OH)D concentrations measured were not comparable. To evaluate whether the three methods had the same ability to classify patients into different categories of vitamin D levels, we categorized results obtained by each method in reference classes. Lumipulse categorized most patients into the class with the lowest 25(OH)D concentrations (<20 ng/mL) whereas Elecsys ranked the lowest number. Conclusions: Liaison XL and Elecsys have shown good accuracy compared to Lumipulse in measuring 25(OH)D levels. Nevertheless, the assays were not interchangeable due to the lack of comparability of results as well as to the disagreement in classification of hormone deficiency or sufficiency.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.