Animal killing for food production and the related operations are events that may induce pain, stress, fear and other forms of suffering to the animals. To face this problem and guarantee the animal welfare, the EU has adopted the Regulation (EC) N. 1099/2009 on the protection of animals at the time of killing. Electrical water bath stunning is one of the methods used in commercial slaughterhouses to protect poultry welfare. In particular, this method induces unconsciousness into the birds due to run of electrical current through the head and body. The aim of the present work was to find an optimal setting of electrical parameters to obtain an effective water bath stunning in a commercial poultry slaughterhouse. Moreover, the influence of the tested electrical parameters on meat quality was evaluated. All the experiments confirmed that high stunning frequencies induce a lower occurrence of lesions on carcasses but, on the other hand, require greater current intensities to be effective. A frequency of 750 Hz and an average current intensity of 200 mA for each bird in the water bath resulted as the best combination of electrical parameters to obtain a proper stunning without any consequence on the meat quality.
The effects of different amounts and frequencies of stunning sine wave alternating current were investigated under field conditions. Seven hundred and fifty broilers were stunned in an electrical water bath with an average root mean square (RMS) current of 150, 200, and 250 mA and frequencies of 200, 400, 600, 800, and 1,200 Hz. The occurrence of corneal reflex, spontaneous eye blinking, and a positive response to a painful stimulus were monitored and recorded immediately after the stunning and at 20 s post-stun. Statistical analysis showed that the electrical stunning frequency (P=0.0004), the stunning RMS current (P<0.0001) and the interaction between stunning frequency and stunning current (P<0.0001) had a significant effect on the occurrence of animals experiencing an abolition of corneal reflex at 20 s post-stun.At a current of 150 mA, the probability of a successful stun was over 90% at 200 Hz, approximately 40% at 400 Hz, and below 5% for frequencies greater than 600 Hz. So, stunning at frequencies greater than 600 Hz cannot be recommended when a RMS current of 150 mA is applied. The maximum probability of a successful stun was obtained for a current level of 200 mA at 400 Hz and for a current level of 250 mA at 400 and 600 Hz, whereas the stunning treatments at 1,200 Hz provided the lowest probability of a successful stun. Assessment of spontaneous eye blinking and responses to comb pinching confirmed the indications coming from the analysis of corneal reflex.
The use of carbon monoxide (CO) in fresh fish has generated considerable debate. Carbon monoxide is used to treat fresh fish in order to retain its fresh red appearance for a longer period. It reacts with the oxy-myoglobin to form a fairly stable cherry red carboxy-myoglobin complex that may mask spoilage, because the CO-complex can be stable beyond the microbiological shelf life of the meat. The presence of CO in tuna fish (Thunnus Albacares) has been investigated by means of optical spectroscopy. Formation of the CO adduct can be easily detected by the combined analysis of electronic absorption spectra in their normal and second derivative modes, monitoring the intense Soret band at 420 nm. Samples were judged as CO treated when their levels were higher than 200 ng/g. Only two positive samples out of 29 analyzed were detected. The high level of uncertainty (0.30) of the method requires the use of more specific and sensitive methods for confirmatory analysis.
Food allergies and intolerances have increased during the last decades and regulatory authorities have taken different measures to prevent and manage consumers’ adverse reactions, including correct labelling of foods. Aim of this work was to search for soybean and lactose in meat products and meat preparations taken from retail in some provinces of Campania Region (Southern Italy) and to evaluate the food labels compliance with Regulation (EU) n.1169/2011. Soybean and lactose were searched using commercial kits in n. 58 samples of meat products produced in or distributed by 19 establishments, and in n. 55 samples of meat products and n. 8 of meat preparations produced in 21 plants. All samples were selected on the basis of the absence of any information on the labels about the presence of the two searched allergens, with the exception of n. 5 samples tested for lactose. Traces of soybean were detected in 50 out of the 58 examined samples, at concentrations up to 0.93 mg kg–1. Only two samples contained levels above the detection limit of 0.31 mg kg–1. Lactose levels ranging from 0.11 to 2.95 g/100 g, i.e. above the detection limit, were found in all the tested samples (n. 63). The results of the present research underline the need for careful controls and planning by operators as part of the self-control plans, and deserve attention from the competent authorities considering not only the consumers’ health but also the great attention media pay to regulations providing consumers with information on food.
In Europe sulfur dioxide (SO2) and sulfites in foods and beverages at concentrations of more than 10 mg kg–1 or 10 mg L–1 expressed as SO2 equivalents are subject to mandatory labelling. In fresh meats the addition of sulfites is not admitted because of their unlawful use to give the product a more attractive appearance. Aim of the study was to detect sulfites in meat product sampled in 19 commercial shops of Lazio Region. In n=12 samples, sulfites were present at different concentrations and no indication for them was reported on the label. Sulfites concentrations ranged from 13.3 to 1278.9 mg kg–1. The results of the present investigation underline the need for better controls by operators, not only under the food information but also in the consumers’ health perspective.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.