[1] Time correlated high-speed video and electromagnetic data for 15 cloud-to-ground and intracloud lightning flashes reveal bursts of light, bright enough to be seen through intervening cloud, during the initial breakdown (IB) stage and within the first 3 ms after flash initiation. Each sudden increase in luminosity is coincident with a CG type (12 cases) or an IC type (3 cases) IB pulse in fast electric field change records. The E-change data for 217 flashes indicate that all CG and IC flashes have IB pulses. The luminosity bursts of 14 negative CG flashes occur 11-340 ms before the first return stroke, at altitudes of 4-8 km, and at 4-41 km range from the camera. In seven cases, linear segments visibly advance away from the first light burst for 55-200 ms, then the entire length dims, then the luminosity sequence repeats along the same path. These visible initial leaders or streamers lengthen intermittently to about 300-1500 m. Their estimated 2-D speeds are 4-18 Â 10 5 m s À1 over the first few hundred microseconds and decrease by about 50% over the first 2 ms. In other cases, only a bright spot or a broad area of diffuse light, presumably scattered by intervening cloud, is visible. The bright area grows larger over 20-60 ms before the luminosity fades in about 100 ms, then this sequence may repeat several times. In several flashes, a 1-2 ms period of little or no luminosity and small E-change is observed following the IB stage prior to stepped leader development.
[1] Three-dimensional lightning mapping observations are compared to cloud charge structures and electric potential profiles inferred from balloon soundings of electric field in New Mexico mountain thunderstorms. For six individual intracloud and cloud-to-ground flashes and for a sequence of 36 flashes in one storm, the comparisons consistently show good agreement between the altitudes of horizontal lightning channels and the altitudes of electric potential extrema or wells. Lightning flashes appear to deposit charge of opposite polarity in relatively localized volumes within the preexisting lower positive, midlevel negative, and upper positive charge regions associated with the potential wells. The net effect of recurring lightning charge deposition at the approximate levels of potential extrema is to increase the complexity in the observed storm charge structure. The midlevel breakdown of both normal intracloud flashes and negative cloud-to-ground flashes is observed to be segregated by flash type into the upper and lower parts of the deep potential well associated with the midlevel negative charge. The segregation is consistent with perturbations observed in the bottom of the negative potential well due to embedded positive charge that was probably deposited by earlier flashes. It is also consistent with an expected tendency for vertical breakdown to begin branching horizontally before reaching the local potential minimum. The joint observations reconcile the apparent dichotomy between the complex charge structures often inferred from balloon soundings through storms and the simpler structures often inferred from lightning measurements.
Abstract. Electric field (E) soundings through convective regions of mesoscale convective systems (MCSs) are examined in this paper. Ten E soundings through updrafts in MCS convective regions and five soundings in MCS convective regions outside updrafts are used to show that a typical electrical structure exists in this region. These 15 E soundings plus one other previously published sounding, which is included in this analysis, comprise all known soundings in the convective region of MCSs. The basic charge structure identified in MCS updrafts consists of four charge regions, alternating in polarity, with the lowest region positive and the highest region negative. The basic charge structure outside updrafts in MCS convective regions has six charge regions, alternating in polarity, with a positive charge region lowest. Maximum E magnitudes of both polarities are larger and are located at lower heights in soundings outside updrafts compared to those within updrafts. Excepting the upper positive charge, inferred charge regions are shallower and have larger charge densities outside updrafts. The center of the main negative charge is lower and warmer outside updrafts (5.5 km,-6.2øC) than within updrafts (6.9 km,-15.7øC). These features inside and outside updrafts are incorporated in a new conceptual model of MCS convective region charge structure. Also, an expanded conceptual model is developed, using previously published data from other parts of MCSs. This more complete conceptual model shows the typical electrical charge, airflow, and reflectivity features in the stratiform region, the transition zone, and the convective region of midlatitude mesoscale convective systems.
Abstract. In this paper, results from nearly 50 electric field soundings through convective regions of mesoscale convective systems (MCSs), isolated supercelIs, and isolated New Mexican mountain storms are compared and synthesized. These three types of thunderstorm convection are found to have a common, basic electrical structure. Within convective updrafts the basic charge structure has four charge regions, alternating in polarity, and the lowest is positive. Outside updrafts of convection there are typically at least six charge regions, alternating in polarity, and the lowest is again positive. Among the three storm types, there are differences in the heights and temperatures at which the basic four charge regions are found in updrafts. The height (temperature) of the center of the main negative charge region averages 6.93 km (-16øC) in MCS convective region updrafts, 9.12 km (-22øC) in supercell updrafts, and 6.05 km (-7øC) in New Mexican mountain storm updrafts. In updraft soundings through all three storm types, the center height of the main negative charge region increases with increasing average balloon ascent rate and updraft speed at a rate of about 0.3 km per 1 rn s -1, with a correlation coefficient of 0.94.A schematic illustrates the basic four-and six-charge structure for thunderstorm convective regions, and it is offered as an improved model for thunderstorm charge structure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.