Esomeprazole improved PEF in subjects with asthma who presented with both GERD and NOC. In subjects without both GERD and NOC, no improvement could be detected.
Patients with primary immunodeficiency disease (PIDD) typically require life-long intravenous (IV) or subcutaneous (SC) immunoglobulin (Ig) replacement therapy to prevent recurrent infections. The efficacy, safety, and pharmacokinetics of a highly concentrated (20 %) Ig preparation for SC administration (IGSC 20 %) were evaluated in a prospective trial in patients with PIDD. A total of 74 patients (aged 3–83 years) received 4327 IGSC 20 % infusions over a median of 380.5 days. The rate of validated serious bacterial infections was 0.012 event/patient-year (p < 0.0001 compared with the historical control), and the annualized rate of infection was 2.41 events/patient. Median IgG trough levels were >14.5 g/l. The median maximum infusion rate was 60 ml/h/site (range 4.4–180), resulting in a median infusion duration of 0.95 h. A volume ≥30 ml was infused per site in 74.8 % of IGSC 20 % infusions. Most (84.9 %) infusions were administered using ≤2 infusion sites; for 99.8 % of infusions, there was no need to interrupt/stop administration or reduce the infusion rate. No related serious adverse event (AE) occurred during IGSC 20 % treatment; related non-serious AEs occurred at a rate of 0.036 event/infusion. The incidence of related local AEs was 0.015 event/infusion and of related systemic AEs was 0.021 event/infusion; most were mild in severity, none severe. Increased infusion rates or volumes were not associated with higher AE rates. The investigated IGSC 20 % treatment was shown to be effective and safe, enabling higher infusion rates and volumes per site compared to conventional SC treatments, resulting in fewer infusion sites and shorter infusion durations.Electronic supplementary materialThe online version of this article (doi:10.1007/s10875-016-0327-9) contains supplementary material, which is available to authorized users.
SummaryPrimary antibody deficiencies require lifelong replacement therapy with immunoglobulin (Ig)G to reduce the incidence and severity of infections. Both subcutaneous and intravenous routes of administering IgG can be effective and well tolerated. Treatment regimens can be individualized to provide optimal medical and quality-of-life outcomes in infants, children, adults and elderly people. Frequency, dose, route of administration, home or infusion-centre administration, and the use of self-or health-professionaladministered infusion can be tailored to suit individual patient needs and circumstances. Patient education is needed to understand the disease and the importance of continuous therapy. Both the subcutaneous and intravenous routes have advantages and disadvantages, which should be considered in selecting each patient's treatment regimen. The subcutaneous route is attractive to many patients because of a reduced incidence of systemic adverse events, flexibility in scheduling and its comparative ease of administration, at home or in a clinic. Self-infusion regimens, however, require independence and self-reliance, good compliance on the part of the patient/parent and the confidence of the physician and the nurse. Intravenous administration in a clinic setting may be more appropriate in patients with reduced manual dexterity, reluctance to self-administer or a lack of self-reliance, and intravenous administration at home for those with good venous access who prefer less frequent treatments. Both therapy approaches have been demonstrated to provide protection from infections and improve health-related quality of life. Data supporting current options in IgG replacement are presented, and considerations in choosing between the two routes of therapy are discussed.
Purpose The present study was designed to evaluate the efficacy and safety of a novel, 10% liquid formulation of intravenous immunoglobulin, stabilized with 250 mmol/L L-proline (Privigen®), in patients with primary immunodeficiency disease. Materials and Methods Eighty adults and children diagnosed with common variable immunodeficiency or X-linked agammaglobulinemia received intravenous Privigen® infusions (200-888 mg/kg) at 3-or 4-week intervals over a 12-month period, according to their previously established maintenance dose. The primary endpoint was the annual rate of acute serious bacterial infections. Results There were six episodes of acute serious bacterial infections, corresponding to an annual rate of 0.08; the annual rate for all infections was 3.55. Mean serum IgG trough levels were between 8.84 and 10.27 g/L. A total of 1,038 infusions were administered, most of them at the maximum rate permitted (8.0 mg kg −1 min −1 ). Temporally associated adverse events, possibly or probably related to
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.