Background Dislocation after revision THA is a common complication. Large heads have the potential to decrease dislocation rate, but it is unclear whether they do so in revision THA.Questions/purposes We therefore determined whether a large femoral head (36 and 40 mm) resulted in a decreased dislocation rate compared to a standard head (32 mm). Methods We randomized 184 patients undergoing revision THA to receive either a 32-mm head (92 patients) or 36-and 40-mm head (92 patients) and stratified patients by surgeon. The two groups had similar baseline demographics. The primary end point was dislocation. Qualityof-life (QOL) measures were WOMAC and SF-36. The mean followup for dislocation was 5 years (range, 2-7 years); the mean followup for QOL was 2.2 years (range, 1.6-4 years). Results In the 36-and 40-mm head group, the dislocation rate was 1.1% (one of 92) versus 8.7% (eight of 92) for the 32-mm head. There was no difference in QOL outcomes between the two groups. Conclusions Our observations confirm a large femoral head (36 or 40 mm) reduces dislocation rates in patients undergoing revision THA at short-term followup. We now routinely use large heads with a highly crosslinked polyethylene acetabular liner in all revision THAs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.