PLTs derived from BCs, obtained from either fresh or overnight-stored WB processed on the novel automated Atreus 2C+ system, were equivalent to control PLTs with regard to PLT in vitro characteristics during 7 days of storage. Stable recovery of PLTs and satisfactory PLT content according to current standards were also found.
From these in vitro data, blood components produced using the Atreus appear suitable for clinical use, with no clinically significant difference in the quality of components from WB held at ambient temperature overnight with or without active cooling.
From these in vitro data, PC produced from buffy coats prepared using the Atreus appear suitable for clinical use, and WB may be held at ambient temperature overnight without the use of active cooling devices. Optimizing the secondary processing conditions to handle Atreus 2C+ derived BC may increase the platelet yield.
Adding PAS immediately or 2 hours after collection does not result in different in vitro quality of PLTs stored up to 7 days. The good recovery of clotting factors with no signs of activation indicates a good quality of CP.
Background: The aim of this study was to provide data on concurrent red blood cell (RBC) and platelet (PLT) apheresis with RBC in-line leukoreduction and automated addition of saline-adenine-glucose-mannitol (SAGM) using the new version (V6.0) of Trima Accel®. Methods: In this two-center paired study, each subject completed a test and a control procedure with an interval of 9 weeks between procedures. In the test arm, single RBC and PLT units were collected on the Trima Accel V6.0 (in-line leukofiltration and automated addition of SAGM). In the control arm, they were collected on Trima Accel V5.1/V5.2 (post-collection leukoreduction, manual SAGM addition). RBC percent hemolysis, potassium concentration and adenosine triphosphate over storage, hemoglobin (Hb) yield, and residual white blood cells (WBC) were determined. Results: 34 subjects successfully completed both test and control procedures. Post-storage hemolysis was similar in both groups, and all values were less than 0.8% for both arms. Residual WBC counts in all RBC units were less than 1 × 106/unit. In-line processed RBC units (V6.0) have a significantly higher volume and more Hb/unit due to filtration recovery improvements. All procedures were well tolerated by the subjects. Conclusion: In-line filtration and automated addition of storage solution on Trima Accel V6.0 allows collection of ready-to-use RBC units that meet EU requirements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.