BackgroundThe current surgical procedure of choice for lumbar intervertebral disc (IVD) herniation is discectomy. However, defects within IVD produced upon discectomy may impair tissue healing and predispose patients to subsequent IVD degeneration. This study aimed to investigate whether the use of an acellular bioresorbable ultra-purified alginate (UPAL) gel implantation system is safe and effective as a reparative therapeutic strategy after lumbar discectomy.MethodsHuman IVD cells were cultured in a three-dimensional system in UPAL gel. In addition, lumbar spines of sheep were used for mechanical analysis. Finally, the gel was implanted into IVD after discectomy in rabbits and sheep in vivo.FindingsThe UPAL gel was biocompatible with human IVD cells and promoted extracellular matrix production after discectomy, demonstrating sufficient biomechanical characteristics without material protrusion.InterpretationThe present results indicate the safety and efficacy of UPAL gels in a large animal model and suggest that these gels represent a novel therapeutic strategy after discectomy in cases of lumbar IVD herniation.FundGrant-in-Aid for the Ministry of Education, Culture, Sports, Science, and Technology of Japan, Japan Agency for Medical Research and Development, and the Mochida Pharmaceutical Co., Ltd.
A method for gait analysis using wearable acceleration sensors and gyro sensors is proposed in this work. The volunteers wore sensor units that included a tri-axis acceleration sensor and three single axis gyro sensors. The angular velocity data measured by the gyro sensors were used to estimate the translational acceleration in the gait analysis. The translational acceleration was then subtracted from the acceleration sensor measurements to obtain the gravitational acceleration, giving the orientation of the lower limb segments. Segment orientation along with body measurements were used to obtain the positions of hip, knee, and ankle joints to create stick figure models of the volunteers. This method can measure the three dimensional positions of joint centers of the hip, knee, and ankle during movement. Experiments were carried out on the normal gait of three healthy volunteers. As a result, the flexion-extension (F-E) and the adduction-abduction (A-A) joint angles of the hips and the flexion-extension (F-E) joint angles of the knees were calculated and compared with a camera motion capture system. The correlation coefficients were above 0.88 for the hip F-E, higher than 0.721 for the hip A-A, better than 0.924 for the knee F-E. A moving stick figure model of each volunteer was created to visually confirm the walking posture. Further, the knee and ankle joint trajectories in the horizontal plane showed that the left and right legs were
High-MW CL HA exerts potential chondroprotective effects and produces superior friction coefficients. Our results suggest that HA600 delays the progression of OA effectively and improves joint lubrication significantly.
In synovial joints, friction between articular surfaces leads to shear stress within the cartilaginous tissue, which might result in tissue rupture and failure. Joint friction depends on synovial lubrication of the articular surfaces, which can be altered due to compressive loading. Therefore, we hypothesized that the frictional coefficient of the temporomandibular joint (TMJ) is affected by the magnitude and duration of loading. We tested this by measuring the frictional coefficient in 20 intact porcine TMJs using a pendulum-type friction tester. The mean frictional coefficient was 0.0145 (SD 0.0027) after a constant loading of 50 N during 5 sec. The frictional coefficient increased with the length of the preceding loading duration and exceeded 0.0220 (SD 0.0014) after 1 hr. Application of larger loading (80 N) resulted in significantly larger frictional coefficients. In conclusion, the frictional coefficient in the TMJ was proportional to the magnitude and duration of joint loading.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.