The operating mechanism, particularly the carrier injection mechanism, of a hybrid organic-inorganic light-emitting diode (HOILED) is reported. Asymmetric hole injection has been observed in a symmetric hole-only device, which has two identical interfaces between a conducting polymer and a metal oxide. A HOILED having a layer of molybdenum oxide (MoO 3 ) deposited on a layer of poly(dioctylfluorene-alt-benzothiadiazole) (F8BT) demonstrated a markedly enhanced hole injection, four orders of magnitude higher on one side of the structure than on the other side. This enhanced hole injection is considered to initiate the operation of the HOILED. X-ray photoelectron spectra (XPS) analysis revealed that Mo deposited on the surface of F8BT was reduced compared to that deposited Mo below the film of F8BT. It is suggested that a chemical interaction between the metal oxide and the organic material affects carrier injection.
Matsuse, H, Hashida, R, Takano, Y, Omoto, M, Nago, T, Bekki, M, and Shiba, N. Walking exercise simultaneously combined with neuromuscular electrical stimulation of antagonists resistance improved muscle strength, physical function, and knee pain in symptomatic knee osteoarthritis: a single-arm study. J Strength Cond Res 31(1): 171-180, 2017-A hybrid training system (HTS) was developed as a way to combine the application of electrical stimulation and voluntary contraction. Moreover, we developed a novel training method using HTS during walking (HTSW). This study was designed to evaluate the effect of HTSW on muscle strength, physical function, and knee pain in knee osteoarthritis (KOA). Eleven subjects (age: 74.0 ± 8.5 years) participated and performed HTSW for 30 minutes 3 times a week for 12 weeks. Isokinetic knee extension/knee flexion torque, muscle volume, one-leg standing test (OST), functional reach test, 10-m maximum gait speed, timed up and go test, 6-minute walking test, knee pain using Visual Analog Scale (VAS), and Japan Knee Osteoarthritis Measure (JKOM) were assessed. Knee extension torque significantly increased from 1.02 ± 0.29 N·m·kg pretraining to 1.23 ± 0.33 N·m·kg posttraining (P < 0.01, ES = 0.68). Knee flexion torque significantly increased from 0.65 ± 0.18 N·m·kg pretraining to 0.78 ± 0.17 N·m·kg posttraining (p < 0.01). Muscle volume significantly increased from 9.00 ± 2.84 mm pretraining to 10.37 ± 3.16 mm at the end of training (p ≤ 0.05). All the physical functions except OST were significantly improved. The JKOM score improved from 26.7 ± 18.30 pretraining to 17.2 ± 14.02 at the end of training (p < 0.01). The VAS score significantly decreased from 35.4 ± 22.59 pretraining to 16.5 ± 19.73 at the end of training (p ≤ 0.05). Hybrid training system during walking may be an effective training method for the treatment of people with KOA.
BackgroundMusculoskeletal atrophy is one of the major problems of extended periods of exposure to weightlessness such as on the International Space Station (ISS). We developed the Hybrid Training System (HTS) to maintain an astronaut’s musculoskeletal system using an electrically stimulated antagonist to resist the volitional contraction of the agonist instead of gravity. The present study assessed the system’s orbital operation capability and utility, as well as its preventative effect on an astronaut’s musculoskeletal atrophy.MethodsHTS was attached to the non-dominant arm of an astronaut staying on the ISS, and his dominant arm without HTS was established as the control (CTR). 10 sets of 10 reciprocal elbow curls were one training session, and 12 total sessions of training (3 times per week for 4 weeks) were performed. Pre and post flight ground based evaluations were performed by Biodex (muscle performance), MRI (muscle volume), and DXA (BMD, lean [muscle] mass, fat mass). Pre and post training inflight evaluations were performed by a hand held dynamometer (muscle force) and a measuring tape (upper arm circumference).ResultsThe experiment was completed on schedule, and HTS functioned well without problems. Isokinetic elbow extension torque (Nm) changed -19.4% in HTS, and -21.7% in CTR. Isokinetic elbow flexion torque changed -23.7% in HTS, and there was no change in CTR. Total Work (Joule) of elbow extension changed -8.3% in HTS, and +0.3% in CTR. For elbow flexion it changed -23.3% in HTS and -32.6% in CTR. Average Power (Watts) of elbow extension changed +22.1% in HTS and -8.0% in CTR. For elbow flexion it changed -6.5% in HTS and -4.8% in CTR. Triceps muscle volume according to MRI changed +11.7% and that of biceps was +2.1% using HTS, however -0.1% and -0.4% respectively for CTR. BMD changed +4.6% in the HTS arm and -1.2% for CTR. Lean (muscle) mass of the arm changed only +10.6% in HTS. Fat mass changed -12.6% in HTS and -6.4% in CTR.ConclusionsThese results showed the orbital operation capability and utility, and the preventive effect of HTS for an astronaut’s musculoskeletal atrophy. The initial flight data together with the ground data obtained so far will be utilized in the future planning of human space exploration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.