A 68-year-old man in whom a prostate cancer biochemical recurrence was being investigated was referred for a full-body 68Ga–prostate-specific membrane antigen PET/CT. Focal uptake in a lesion on the choroid plexus projection was detected. Patient had no neurological complaints. A previous MRI performed 4 years ago showed the same lesion. According to the location and radiological and clinical characteristics, the diagnosis of meningioma was defined. The interpretation of prostate-specific membrane antigen PET/CT must take into account the low frequency of metastases in sites such as the central nervous system, and the possibility of intense uptake in lesions unrelated to prostate cancer.
O Câncer é uma doença de alta prevalência e letalidade, sendo uma das principais causas de morte no Brasil e no mundo. Nas últimas décadas, grandes avanços foram alcançados na luta contra o câncer, com alguma tradução em curabilidade. Contudo, esses avanços ainda não são suficientes, de modo que o prognóstico do paciente com câncer ainda é, geralmente, desfavorável. De fato, há ainda diversas lacunas em nosso conhecimento a respeito dessa complexa e heterogênea doença. Diversos tratamentos contra o câncer já estão disponíveis à prática clínica - e outros ainda estão sendo desenvolvidos - uma delas a quimioterapia, tanto a tradicional quando a alvo dirigida, utilizada, sobretudo, como tratamento primário contra doença metastática ou secundário contra doença local ou localmente avançada. Diversos fatores podem atuar, através de vários mecanismos, de modo a determinar a falha do tratamento quimioterápico. Esses fatores estão distribuídos ao longo de diversas escalas biológicas, do nível molecular ao socioeconômico, tornando uma visão holística do tratamento um grande desafio, prejudicando a compreensão acerca do que pode dar errado. O objetivo deste trabalho é ser uma leitura compreensiva - mas não superficial - dos muitos fatores que influenciam o sucesso de quimioterapia. Deste modo, o resultado foi a presente discussão, na qual foram expostos avanços recentes, desafios a serem superados e novos caminhos a serem explorados na área.
Objective: To evaluate the effect that external cooling of the salivary glands (ECSG) has on the uptake of gallium-68-labeled prostate-specific membrane antigen (68Ga-PSMA), as an indirect assessment of the capacity of ECSG to reduce the local dose in lutetium-177-PSMA-617 radioligand therapy. Materials and Methods: Ten patients with prostate cancer were submitted to 68Ga-PSMA positron emission tomography/computed tomography with unilateral ECSG. The ECSG was started at 30 min before the injection of the radiotracer and maintained until the end of image acquisition (1 h after injection). Each salivary gland was assessed by determining the maximum, mean, and peak standardized uptake values (SUVmax, SUVmean, and SUVpeak, respectively). The volume of each gland was determined in a volume of interest delineated by a threshold SUVmax of 10%. Paired Student’s t-tests were used in order to compare the results. Results: In terms of the SUV parameters, there were no statistically significant differences between the cooled and contralateral salivary glands. However, the mean volume was 27% lower in the cooled parotid glands than in the contralateral parotid glands (p = 0.004). Conclusion: The use of ECSG does not appear to reduce 68Ga-PSMA uptake by the salivary glands. In addition, there is yet no evidence that ECSG is effective in preventing salivary gland toxicity.
Introduction: Techniques using PSMA radioligands have emerged as diagnostic and therapeutic alternatives in prostate cancer. Significant adverse events resulting from using beta-emitters such as 177Lu-PSMA for castration-resistant prostate cancer therapy include sialotoxicity and xerostomia. Sialotoxicity ranges from 8% mild to moderate up to 10% interruption of treatment, depending on the compound used, due to the physiological expression of PSMA in the salivary glands and consequent radioligand uptake. Cooling with icepacks emerged as a possible intervention to prevent this event. The rationale is that cold- induced vasoconstriction would lead to a reduction of the perfusion of the gland, similarly to scalp cooling applied in some chemotherapies. Although empirically used in European protocols, the efficacy of this technique was assessed in only one study, with no evidence of success. The objective of this work was to analyze the efficacy of salivary gland cooling in the reduction of PSMA radioligand uptake.Methodology: Unilateral cooling of the salivary glands was performed for 10 prostate cancer patients submitted to PET-CT with Ga68PSMA, a compound used for diagnostic purposes and validated mainly in biochemical recurrence scenario. For cooling, icepacks were coupled to a device that attached them to one of the patient's parotid gland. Cooling started 30 minutes before the injection of the radiopharmaceutical. The test was started 1h after the injection (acquisition t1), with an approximate duration of 30 minutes. A delayed image was made 4h after the injection (acquisition t4). The cooling was suspended just after the t1 acquisition. The packs were replaced every 30 minutes, and their temperature measured and recorded using infrared thermometers, for temperature standardization. Using OsiriX Dicom Viewer software, each of the glands (cooled parotid and control, cooled submandibular and control) was quantitatively assessed by the standardized maximum, mean and peak uptake values (SUVmax, SUVmean, and SUVpeak). The gland was delimited through an isocontour generated from a threshold of 10% of the SUVmax within a defined volume of interest (VOI). These four parameters were compared through the paired Student's T-test using R Commander software.Results: There was no statistically significant reduction in any of the SUV parameters in the cooled glands compared to contralateral controls, both in t1 in t4. Regarding the submandibular glands, there were also found no alterations of statistical relevance, but the means of the three SUV parameters were higher in the cooled glands that in the controls.Discussion: Results indicated no significant reduction of the radiation absorbed dose by cooled salivary glands. Despite the small sample size, that could reduce the ability to detect significant variations, results allow inferring that biological effects, if present, are probably small and of little clinical significance. Therefore, it was considered that results did not justify performing further exams since this is a high cost and complexity technique. The present findings corroborate with the other mentioned study.Conclusion: The cooling of the salivary glands does not significantly reduce their uptake of radiopharmaceuticals, and no evidence supports this technique for sialotoxicity and xerostomia prevention in clinical practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.