X-ray zone plates made from gold are common optical components used in X-ray imaging experiments. These nanostructures are normally fabricated using a combination of electron-beam lithography and gold electroplating with cyanide gold baths. In this study, we present a gold electroplating process in a miniaturized gold-suplphite bath. The miniaturization is enabled by on-chip reference plating areas with well defined sizes, offering a reliable way to control the height of the structures by carefully choosing the plating time at a given current density in accordance with a calibration curve. Fabricated gold zone plates were successfully used in X-ray imaging experiments with synchrotron radiation. Although gold electroplating of nanostructures is a well-established method, details about the actual process are often missing in the literature. Therefore, we think that our detailed descriptions and explanations will be helpful for other researchers that would like to fabricate similar structures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.