Ambient desorption/ionization mass spectrometry (ADI-MS) is widely used as a rapid screening tool of samples in their native state without sample preparation. While analysis times are much less than 1 min per sample, one challenge of ADI-MS is the possibility to perform quantitative analysis of analytes in complex matrices. Typically, the goal is to probe a variety of different analytes in a complex matrix from a solid, liquid, or otherwise uncharacterized surface in the open air in front of the MS inlet. In this study, it is demonstrated that a carefully selected surface for analyte spot sampling and co-deposited isotopically labeled standards both significantly improve the capabilities of flowing atmospheric-pressure afterglow (FAPA) high-resolution (HR) MS for direct quantitative analysis. Specifically, a systematic study of different surfaces (glass, steel mesh, high-performance thin-layer chromatography (HPTLC) stationary phases including silica, reversed-phase (RP)-modified silica, and cyano (CN)-modified silica) and their suitability for spot sampling with FAPA-MS was performed. A set of different caffeine-containing standards and beverages (Red Bull, Coca-Cola, coffee, and black tea) was deposited on the surfaces and direct FAPA-HR-MS analysis of caffeine was performed using internal calibration with co-deposited 13C3-caffeine. For TLC surfaces, it was demonstrated that quantitative results could be achieved with the matrix and concomitants present and that a preceding chromatographic separation was not mandatory for this application. In addition, the use of a CN-HPTLC surface resulted in a significantly more intense caffeine signal in the beverage samples compared to the other surfaces studied, with the highest increase compared to the silica (200-fold higher) and the lowest increase compared to the steel mesh (30-fold higher). The utilization of TLC-based surfaces as sample carriers is considered an attractive tool in the ADI-MS toolbox for fast and efficient mass spectrometric investigations of complex samples without time-consuming sample preparation.
Graphical Abstract
Two representative organic photoreactions, namely a bimolecular photocycloaddition and a monomolecular photorearrangement, are presented that are accelerated when the reaction is performed “on‐water”, that is, at the water‐substrate interface with no solvation of the reaction components. According to the established models of ground‐state reactions “on‐water”, the enhanced efficiency of the photoreactions is explained by hydrophobic effects (Paternó‐Büchi reaction) or specific hydrogen bonding (di‐π‐methane rearrangement) at the water‐substrate interface that decrease the energy of the respective transition state. These results point to the potential of this approach to conduct photoreactions more efficiently in an ecologically favorable medium.
Ambient desorption/ionization mass spectrometry (ADI-MS) has been broadly applied to accomplish direct analysis without sample preparation or separation. However, quantification capabilities and analytical performance are sometimes limited. Here, we report signal enhancement effects and improved quantification capabilities in plasma-based ADI-MS, when a flowing atmospheric-pressure afterglow (FAPA) source is used to probe analytes on tailored thin-layer chromatography (TLC) plates. It was found that quantitative results could be achieved when the TLC plate merely served as a sampling plate without a preceding separation step. Specifically, the dynamic response of caffeine, nicotine, acetaminophen, and progesterone was investigated with FAPA-MS on a variety of different TLC surfaces (normal-phase silica, reversed-phase-modified silica, cyano [CN]-modified silica, and dimethyl [RP2]-modified silica). All analytes were studied as single-analyte standards and in a multianalyte mixture to evaluate the effect of sample plates and sample matrix on analytical performance and competitive ionization processes. Overall, dimethyl (RP2)- and CN-modified silica resulted in superior performance compared to other TLC materials. After careful optimization and without the use of internal standards, linear ranges of five orders of magnitude were accessible for caffeine and nicotine. Limits of detection down to femtomole amounts of analyte were achieved. Quantitation limits using RP2-TLC and FAPA-MS were 0.062, 0.062l, 0.31, and 14 pmol for caffeine, nicotine, progesterone, and acetaminophen, respectively. Interestingly, the presence of nicotine at relatively high amounts reduced the signal of the other analytes, an observation that was found to correlate with the differences in the enthalpy of vaporization (Δ Hvap) and proton affinity. To prove the quantitative capabilities, nicotine quantification in a real matrix-heavy e-liquid sample was demonstrated using an isotopically labeled standard. The use of TLC-based surfaces with FAPA-MS can aid in the direct and quantitative mass spectrometric investigation of complex mixtures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.