Purpose: In medial open-wedge high tibial osteotomy (HTO) hinge axis and osteotomy plane influence the resulting anatomy, but accurate angular quantifications using 3D-planning-simulations are lacking. The objectives of this study were developing a standardized and validated 3D-planning method of an HTO and to perform several simulated realignments to explain unintended anatomy changes. Methods: The cutting direction of the main osteotomy was defined parallel to the medial tibial slope and the hinge axis 1.5 cm distal to the lateral plateau. For interobserver testing, this 3D planning was performed on 13 digital models of human tibiae by two observers. In addition, four different hinge axis positions and five differently inclined osteotomy planes each were simulated. The osteotomy direction ranged from medial 0°–30° anteromedial, while the tilt of the osteotomy plane compared to the tibial plateau was −10° to +10°. All anatomic angular changes were calculated using 3D analysis. Results: Multiple HTO plannings by two medical investigators using standardized procedures showed only minimal differences. In the 3D-simulation, each 10° rotation of the hinge axis resulted in a 1.7° significant increase in slope. Tilting the osteotomy plane by 10° resulted in significant torsional changes of 2°, in addition to minor but significant changes in the medial proximal tibial angle (MPTA). Conclusion: Standardized 3D-planning of the HTO can be performed with high reliability using two-observer planning. 3D-simulations suggest that control of the osteotomy plane is highly relevant to avoid unintended changes in the resulting anatomy, but this can be a helpful tool to modify specific angles in different pathologies in the HTO.
Purpose Three-dimensional (3D) printed patient-specific instruments (PSI) have been introduced to increase precision and simplify surgical procedures. Initial results in femoral and tibial osteotomies are promising, but validation studies on 3D planning, manufacturing of patient-specific cutting blocks and 3D evaluation of the attained results are lacking. Methods In this study, patient-specific cutting blocks and spacers were designed, fabricated, and used to perform a high tibial osteotomy (HTO). After segmentation of CT data sets from 13 human tibiae, 3D digital planning of the HTO was performed with a medial opening of 8 mm. These 3D models were used to fabricate patient-specific cutting blocks and spacers. After the surgical procedure, accuracy was evaluated measuring 3D joint angles and surface deviations. Results The lowest mean deviation was found to be 0.57° (SD ± 0.27) for the MPTA. Medial and lateral tibial slope deviated from the 3D planning by an average of 0.98° (SD ± 0.53) and 1.26° (SD ± 0.79), respectively, while tibial torsion deviated by an average of 5.74° (SD ± 3.24). Color analysis of surface deviations showed excellent and good agreement in 7 tibiae. Conclusion With 3D cutting blocks and spacers, the 3D planning of the HTO can be translated into reality with small deviations of the resulting joint angles. Within this study, the results of the individual steps are examined for errors and thus a critical evaluation of this new and promising method for performing patient-specific HTOs is presented.
Background Many radiographic lower limb alignment measurements are dependent on patients’ position, which makes a standardised image acquisition of long-leg radiographs (LLRs) essential for valid measurements. The purpose of this study was to investigate the influence of rotation and flexion of the lower limb on common radiological alignment parameters using three-dimensional (3D) simulation. Methods Joint angles and alignment parameters of 3D lower limb bone models (n = 60), generated from computed tomography (CT) scans, were assessed and projected into the coronal plane to mimic radiographic imaging. Bone models were subsequently rotated around the longitudinal mechanical axis up to 15° inward/outward and additionally flexed along the femoral intercondylar axis up to 30°. This resulted in 28 combinations of rotation and flexion for each leg. The results were statistically analysed on a descriptive level and using a linear mixed effects model. Results A total of 1680 simulations were performed. Mechanical axis deviation (MAD) revealed a medial deviation with increasing internal rotation and a lateral deviation with increasing external rotation. This effect increased significantly (p < 0.05) with combined flexion up to 30° flexion (− 25.4 mm to 25.2 mm). With the knee extended, the mean deviation of hip–knee–ankle angle (HKA) was small over all rotational steps but increased toward more varus/valgus when combined with flexion (8.4° to − 8.5°). Rotation alone changed the medial proximal tibial angle (MPTA) and the mechanical lateral distal femoral angle (mLDFA) in opposite directions, and the effects increased significantly (p < 0.05) when flexion was present. Conclusions Axial rotation and flexion of the 3D lower limb has a huge impact on the projected two-dimensional alignment measurements in the coronal plane. The observed effects were small for isolated rotation or flexion, but became pronounced and clinically relevant when there was a combination of both. This must be considered when evaluating X-ray images. Extension deficits of the knee make LLR prone to error and this calls into question direct postoperative alignment controls. Level of evidence III (retrospective cohort study).
Background Mechanical chest compression (mCPR) offers advantages during transport under cardiopulmonary resuscitation. Little is known how devices of different design perform en-route. Aim of the study was to measure performance of mCPR devices of different construction-design during ground-based pre-hospital transport. Methods We tested animax mono (AM), autopulse (AP), corpuls cpr (CC) and LUCAS2 (L2). The route had 6 stages (transport on soft stretcher or gurney involving a stairwell, trips with turntable ladder, rescue basket and ambulance including loading/unloading). Stationary mCPR with the respective device served as control. A four-person team carried an intubated and bag-ventilated mannequin under mCPR to assess device-stability (displacement, pressure point correctness), compliance with 2015 ERC guideline criteria for high-quality chest compressions (frequency, proportion of recommended pressure depth and compression-ventilation ratio) and user satisfaction (by standardized questionnaire). Results All devices performed comparable to stationary use. Displacement rates ranged from 83% (AM) to 11% (L2). Two incorrect pressure points occurred over 15,962 compressions (0.013%). Guideline-compliant pressure depth was > 90% in all devices. Electrically powered devices showed constant frequencies while muscle-powered AM showed more variability (median 100/min, interquartile range 9). Although physical effort of AM use was comparable (median 4.0 vs. 4.5 on visual scale up to 10), participants preferred electrical devices. Conclusion All devices showed good to very good performance although device-stability, guideline compliance and user satisfaction varied by design. Our results underline the importance to check stability and connection to patient under transport.
Introduction Current gold standard for the treatment of symphyseal disruptions includes anterior plating, almost entirely prohibiting symphyseal mobility and resulting in an iatrogenic arthrodesis followed by high rates of implant failure. Minimally invasive tape suture constructs have been found to maintain the micro mobility of ligamentous injuries, yet still providing sufficient biomechanical stability. Recently, this technique has been primarily investigated for symphyseal disruptions on synthetic pelvic models. Therefore, the aim of this study was to examine the feasibility of this novel flexible osteosynthesis on cadaveric pelvic models based on the following hypothesis: tape suture constructs ensure sufficient biomechanical stability without inhibiting micro mobility of the pubic symphysis for the treatment of symphyseal disruptions and maintain stability during long-term loading. Materials and methods 9 cadaveric anterior pelvic rings were used in this study and a symphyseal disruption was created in every specimen. The specimens were then exposed to short- and long-term vertical and horizontal cyclic loading after treatment with a tape suture construct in criss-cross technique. The mean maximum displacement (mm) during cyclic loading and the corresponding stiffness (N/mm) were measured and compared. Results Regarding both displacement (mm) and corresponding stiffness (N/mm), the tape sutures displayed a significant difference between short- and long-term loading for cranial and caudal vertical loading (p < 0.01) but differences remained non-significant for horizontal loading (p > 0.05). No tape suture suffered from implant failure during long-term loading. Conclusions The tape suture construct displayed sufficient biomechanical stability without exceeding the physiological mobility of 2 mm of the pubic symphysis; however, also maintained the desired micro mobility of the affected joint necessary to prevent an iatrogenic arthrodesis. Further, all tape sutures maintained stability throughout long-term loading.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.