The blood-brain barrier (BBB) limits the delivery of systemically administered drugs to the brain. Methods to circumvent the BBB have been developed, but none are used in standard clinical practice. The lack of adoption of existing methods is due to procedural invasiveness, serious adverse effects, and the complications associated with performing such techniques coincident with repeated drug administration, which is customary in chemotherapeutic protocols. Pulsed ultrasound, a method for disrupting the BBB, was shown to effectively increase drug concentrations and to slow tumor growth in preclinical studies. We now report the interim results of an ultrasound dose-escalating phase 1/2a clinical trial using an implantable ultrasound device system, SonoCloud, before treatment with carboplatin in patients with recurrent glioblastoma (GBM). The BBB of each patient was disrupted monthly using pulsed ultrasound in combination with systemically injected microbubbles. Contrast-enhanced magnetic resonance imaging (MRI) indicated that the BBB was disrupted at acoustic pressure levels up to 1.1 megapascals without detectable adverse effects on radiologic (MRI) or clinical examination. Our preliminary findings indicate that repeated opening of the BBB using our pulsed ultrasound system, in combination with systemic microbubble injection, is safe and well tolerated in patients with recurrent GBM and has the potential to optimize chemotherapy delivery in the brain.
Acoustic characterization of high intensity focused ultrasound ͑HIFU͒ fields is important both for the accurate prediction of ultrasound induced bioeffects in tissues and for the development of regulatory standards for clinical HIFU devices. In this paper, a method to determine HIFU field parameters at and around the focus is proposed. Nonlinear pressure waveforms were measured and modeled in water and in a tissue-mimicking gel phantom for a 2 MHz transducer with an aperture and focal length of 4.4 cm. Measurements were performed with a fiber optic probe hydrophone at intensity levels up to 24 000 W / cm 2 . The inputs to a Khokhlov-Zabolotskaya-Kuznetsov-type numerical model were determined based on experimental low amplitude beam plots. Strongly asymmetric waveforms with peak positive pressures up to 80 MPa and peak negative pressures up to 15 MPa were obtained both numerically and experimentally. Numerical simulations and experimental measurements agreed well; however, when steep shocks were present in the waveform at focal intensity levels higher than 6000 W / cm 2 , lower values of the peak positive pressure were observed in the measured waveforms. This underrepresentation was attributed mainly to the limited hydrophone bandwidth of 100 MHz. It is shown that a combination of measurements and modeling is necessary to enable accurate characterization of HIFU fields.
In high intensity focused ultrasound (HIFU) applications, tissue may be thermally necrosed by heating, emulsified by cavitation, or, as was recently discovered, emulsified using repetitive millisecond boiling caused by shock wave heating. Here, this last approach was further investigated. Experiments were performed in transparent gels and ex vivo bovine heart tissue using 1, 2, and 3 MHz focused transducers and different pulsing schemes in which the pressure, duty factor, and pulse duration were varied. A previously developed derating procedure to determine in situ shock amplitudes and the time-to-boil was refined. Treatments were monitored using B-mode ultrasound. Both inertial cavitation and boiling were observed during exposures, but emulsification occurred only when shocks and boiling were present. Emulsified lesions without thermal denaturation were produced with shock amplitudes sufficient to induce boiling in less than 20 ms, duty factors of less than 0.02, and pulse lengths shorter than 30 ms. Higher duty factors or longer pulses produced varying degrees of thermal denaturation combined with mechanical emulsification. Larger lesions were obtained using lower ultrasound frequencies. The results show that shock wave heating and millisecond boiling is an effective and reliable way to emulsify tissue while monitoring the treatment with ultrasound.
Purpose: The blood-brain barrier (BBB) limits the efficacy of drug therapies for glioblastoma (GBM). Preclinical data indicate that low-intensity pulsed ultrasound (LIPU) can transiently disrupt the BBB and increase intracerebral drug concentrations.Patients and Methods: A first-in-man, single-arm, singlecenter trial (NCT02253212) was initiated to investigate the transient disruption of the BBB in patients with recurrent GBM. Patients were implanted with a 1-MHz, 11.5-mm diameter cranial ultrasound device (SonoCloud-1, CarThera). The device was activated monthly to transiently disrupt the BBB before intravenous carboplatin chemotherapy.Results: Between 2014 and 2016, 21 patients were registered for the study and implanted with the SonoCloud-1; 19 patients received at least one sonication. In 65 ultrasound sessions, BBB disruption was visible on T1w MRI for 52 sonications. Treatment-related adverse events observed were transient and manageable: a transient edema at H1 and at D15. No carboplatin-related neurotoxicity was observed. Patients with no or poor BBB disruption (n ¼ 8) visible on MRI had a median progression-free survival (PFS) of 2.73 months, and a median overall survival (OS) of 8.64 months. Patients with clear BBB disruption (n ¼ 11) had a median PFS of 4.11 months, and a median OS of 12.94 months.Conclusions: SonoCloud-1 treatments were well tolerated and may increase the effectiveness of systemic drug therapies, such as carboplatin, in the brain without inducing neurotoxicity. NOTE: Data are median (range). Idbaih et al. NOTE: The occurrence of each AE is listed as well as the total number of patients affected, as some patients might have experienced the same AE multiple times over the course of therapy.Blood-Brain Barrier Disruption by Ultrasound in GBM www.aacrjournals.org
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.