This study presents data on the application of two different processing techniques of foot parameters and the comparison of their validity and reliability in adults. Twenty-four healthy participants volunteered took part in the study. Three digital scans were obtained from each participant by one experienced investigator. The foot parameters were: Clarke index, 'KY' index of Sztriter-Godunov, heel angle and Wejsflog index. The parameters were identified into two ways: manually using software SolidWorks and by a new computer-aided system. The results of the Spearman's rank correlation suggest a strong positive relationship between parameters obtained from the computer-aided system and manually counted (> 0.9). The current study suggests that computer-aided system is a practical tool for foot type assessment in adults and could be recommended for both research and clinical applications.
Abstract.BACKGROUND: Gait analysis is a useful tool medical staff use to support clinical decision making. There is still an urgent need to develop low-cost and unobtrusive mobile health monitoring systems. OBJECTIVE: The goal of this study was twofold. Firstly, a wearable sensor system composed of plantar pressure insoles and wearable sensors for joint angle measurement was developed. Secondly, the accuracy of the system in the measurement of ground reaction forces and joint moments was examined. METHODS: The measurements included joint angles and plantar pressure distribution. To validate the wearable sensor system and examine the effectiveness of the proposed method for gait analysis, an experimental study on ten volunteer subjects was conducted. The accuracy of measurement of ground reaction forces and joint moments was validated against the results obtained from a reference motion capture system. RESULTS: Ground reaction forces and joint moments measured by the wearable sensor system showed a root mean square error of 1% for min. GRF and 27.3% for knee extension moment. The correlation coefficient was over 0.9, in comparison with the stationary motion capture system. CONCLUSIONS: The study suggests that the wearable sensor system could be recommended both for research and clinical applications outside a typical gait laboratory.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.