We study the mechanical fluctuations of a micrometer sized silicon cantilever subjected to a strong heat flow, thus having a highly nonuniform local temperature. In this nonequilibrium steady state, we show that fluctuations are equivalent to the thermal noise of a cantilever at equilibrium around room temperature, while its mean local temperature is several hundred degrees higher. Changing the mechanical dissipation by adding a coating to the cantilever, we recover the expected rise of fluctuations with the mean temperature. Our work demonstrates that inhomogeneous dissipation mechanisms can decouple the amplitude of thermal fluctuations from the average temperature. This property could be useful to understand out-of-equilibrium fluctuating systems, or to engineer low noise instruments.
In recent years an increasing number of devices and experiments are shown to be limited by mechanical thermal noise. In particular sub-Hertz laser frequency stabilization and gravitational wave detectors, that are able to measure fluctuations of 10−18 m/ √ Hz or less, are being limited by thermal noise in the dielectric coatings deposited on mirrors. In this paper we present a new measurement of thermal noise in low absorption dielectric coatings deposited on micro-cantilevers and we compare it with the results obtained from the mechanical loss measurements. The coating thermal noise is measured on the widest range of frequencies with the highest signal to noise ratio ever achieved. In addition we present a novel technique to deduce the coating mechanical losses from the measurement of the mechanical quality factor which does not rely on the knowledge of the coating and substrate Young moduli.The dielectric coatings are deposited by ion beam sputtering. The results presented here give a frequency independent loss angle of (4.7 ± 0.2) × 10 −4 with a Young's modulus of 118 GPa for annealed tantala from 10 Hz to 20 kHz. For as-deposited silica, a weak frequency dependence (∝ f −0.025 ) is observed in this frequency range, with a Young's modulus of 70 GPa and an internal damping of (6.0 ± 0.3) × 10 −4 at 16 kHz, but this value decreases by one order of magnitude after annealing and the frequency dependence disappears.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.