This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially.
This article has been peer reviewed and published immediately upon acceptance.It is an open access article, which means that it can be downloaded, printed, and distributed freely, provided the work is properly cited. Articles in "Cardiology Journal" are listed in PubMed.
Objective: Most current algorithms for detecting Atrial Fibrillation (AF) rely on Heart Rate Variability (HRV), and only a few studies analyse the variability of Photopletysmography (PPG) waveform. This study aimed to compare morphological features of the PPG curve in patients with AF to those presenting a normal sinus rhythm (NSR) and evaluate their usefulness in AF detection.
Approach: 10-minute PPG signals were obtained from patients with persistent/paroxysmal AF and NSR. Nine morphological parameters (1/ΔT, Pulse Width [PW], Augmentation Index [AI], b/a, e/a, [b-e]/a, Crest Time [CT], Inflection Point Area [IPA], Area and five HRV parameters (Heart rate [HR], Shannon entropy [ShE], root mean square of the successive differences [RMSSD], number of pairs of consecutive systolic peaks [R-R] that differ by more than 50 ms [NN50], standard deviation of the R-R intervals [SDNN]) were calculated.
Main Results: Eighty subjects, including 33 with AF and 47 with NSR were recruited. In univariate analysis five morphological features (1/ΔT, p<0.001; b/a, p<0.001; [b-e]/a, p<0.001; CT, p=0.011 and Area, p<0.001) and all HRV parameters (p=0.01 for HR and p<0.001 for others) were significantly different between the study groups. In the stepwise multivariate model (Area under the curve [AUC] = 0.988 [0.974-1.000]), three morphological parameters (PW, p<0.001; e/a, p=0.011; (b-e)/a, p<0.001) and three of HRV parameters (ShE, p=0.01; NN50, p<0.001, HR, p = 0.01) were significant. 
Significance: There are significant differences between AF and NSR, PPG waveform, which are useful in AF detection algorithm. Moreover adding those features to HRV-based algorithms may improve their specificity and sensitivity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.