Purpose To evaluate the agreement of dry, and cycloplegic autorefraction and wavefront-based refraction with subjective refraction. Method 83 subjects aged 19–57 years were included in this cross-sectional study. Refractive status was determined using four methods including subjective refraction, wavefront-based refraction, dry and cycloplegic autorefraction. Refractive data were recorded as sphere, cylinder and spherical equivalent (SE). Power vector components were used to compare the astigmatism obtained using the different methods of refraction. Results The more negative spherical, cylindrical and SE components were obtained using dry autorefraction, wavefront-based refraction and dry autorefraction, respectively. The less negative spherical, cylindrical and SE components were obtained using cycloplegic autorefraction, subjective refraction and cycloplegic autorefraction, respectively. Considering the spherical component, there was a statistically significant hyperopic shift (0.12 ± 0.29 D, p = 0.001) with cycloplegic autorefraction and a significant myopic shift (−0.17 ± 0.32 D, p < 0.001) with dry autorefraction compared to subjective refraction, while the difference between wavefront-based and subjective refraction was not significant statistically (p = 0.145). The calculated cylindrical component using subjective refraction showed statistically significant difference with dry auto-refraction (p < 0.001), cycloplegic auto-refraction (p = 0.041) and wavefront refraction (p < 0.001). The highest correlation with subjective refraction in sphere, cylinder and SE was observed for cycloplegic auto-refraction (r s = 0.967), dry auto-refraction (r s = 0.983) and cycloplegic auto-refraction (r s = 0.982), respectively. Conclusions As subjective refraction is gold standard in our study, sphere in cycloplegic auto-refraction and astigmatism in dry auto-refraction showed better agreement and correlation.
Purpose: To evaluate the long-term outcomes of collagen crosslinking in early keratoconus. Methods: Thirty eyes of twenty patients with early keratoconus were enrolled. Uncorrected visual acuity (UCVA), best spectacle corrected visual acuity (BSCVA), objective refraction, subjective refraction, corneal topography and pachymetry were assessed before and 3, 6, 12 months and 9 years after performing collagen crosslinking surgery. Results: The patients’ mean age was 31.2 ± 5.59 years at nine-year follow-up (range, 25–44 years). The means of preoperative UCVA and BSCVA were 0.57 ± 0.34 and 0.15 ± 0.12 logMAR, respectively, and these values remained stable at the final follow-up (P = 0.990 and P = 0.227, respectively). The mean objective spherical equivalent decreased considerably from –6.00 ± 4.05 D preoperatively to –5.22 ± 3.71 D at the final follow-up (P < 0.05). The mean subjective spherical equivalent was –4.25 ± 2.87 D preoperatively and this value was stable at the last follow-up (P = 0.92). No considerable difference was found between the post- and preoperative mean objective cylinder values (P = 0.34). The mean subjective cylinder value changed significantly from –4.05 ± 1.85 D preoperatively to –3.1 ± 1.42 D at the final follow-up (P < 0.05). The mean central corneal thickness was 496.97 ± 45.95 μm preoperatively and this value was stable at nine-year follow-up (P = 0.183). No significant difference was found between the pre- and postoperative mean maximum and mean minimum corneal curvature values (P = 0.429 and P = 0.248, respectively). There were no significant postoperative complications. Conclusion: Corneal crosslinking in early keratoconus seems to be a safe procedure that can effectively stabilize UCVA, BSCVA, subjective SE and CCT, while improving objective spherical equivalent.
Purpose. To examine the outcomes of keratorefractive surgeries in keratoconus suspect patients. Methods. This study included 192 keratoconus suspects (351 eyes), treated with photorefractive keratectomy (PRK) (211 eyes), Lasik (96 eyes), and Femto-Lasik (44 eyes) surgeries in an eye clinic. The best spectacle-corrected visual acuity (BSCVA) and subjective refraction were evaluated preoperatively and postoperatively (three months and five years after the procedure). The Orbscan II topography system was also used preoperatively and five years after the procedure. Results. The patients’ mean age was 31.6 ± 5.49 years (range: 21–47 years) in the last follow-up. There was no significant difference between the preoperative and postoperative mean values of BSCVA in any of the surgical methods ( P = 0.49). The mean spherical equivalent, cylindrical power, corneal curvature, the thinnest corneal thickness, and the central corneal thickness decreased significantly in the last follow-up ( P < 0.001). Four patients (3.50%) in the PRK group and one patient (1.85%) in the Lasik group needed glasses in the last follow-up. Eleven cases of corneal ectasia were detected in the last follow-up (six eyes of four patients [2.84%] and five eyes of four patients [5.20%] in the PRK and Lasik groups, respectively). Conclusion. In the present study, the high risk of postoperative ectasia was detected in keratoconus suspects following PRK and Lasik surgeries. According to the results, it can be concluded that Femto-Lasik surgery provides better outcomes than Lasik and PRK. Overall, the surgical criteria are suggested to be evaluated case by case, and the patients must be followed up over time to assess the corneal topography and refraction stability.
It is important to predict which astigmatic patients require separate refraction for near vision. This study compared cylindrical components changes by cyclopentolate 1% for the low and high amount of astigmatism. The right eyes of 1014 healthy individuals (307 males and 707 females) with cylindrical refractive power more than −0.5 diopter on autorefractometer were selected. Both male and female patients in the age range of 17–45 years were refracted before and after cycloplegia, using 1% cyclopentolate. All volunteers were classified into 2 subgroups including the lower astigmatism group (−2.25 to −0.50) and the higher astigmatic group (−2.50 to over). Alpines’ method was used to compare the effect of cycloplegic drop on cylindrical power. The mean age in the lower astigmatism group (29.58; 95% CI: 29.18 to 29.99 years) was not significantly different from the higher astigmatic group (29.85; 95% CI: 29.07 to 30.62) and there were no significant differences in gender between these two groups ( P = 0.54 ). Differences between wet and dry refraction in J0 (−0.03; 95% CI:−0.06 to −0.008) and J45 (−0.03; 95% CI:−0.06 to −0.01) were significant only in the higher astigmatic group. Axis changes by the cycloplegic drop in the lower astigmatism group were 3.51 (CI: 3.22 to 3.81) and axis changes by the cycloplegic drop in the higher astigmatism group were 2.21 (CI: 1.73 to 2.49). In patients with a lower amount of astigmatism (−2.25 to −0.50), additional near subjective refraction could be done for precise determination of axis and in patients with a higher amount of astigmatism (−2.50 to over), near subjective refraction might be done for precise determination of power.
Purpose: This study aimed to estimate the agreement of astigmatism between an autorefractor (Topcon), cycloplegic refraction, subjective manifest refraction, front and back corneal astigmatism. Moreover, this study aimed to investigate which factors influence the difference between cycloplegic refraction and subjective manifest refraction in these keratonic eyes.Methods: subjective manifest refraction, Autorefractmeter were measured in 64 keratonic eyes of 43 patients (21-45 years old) before and after using cycloplegic drop. We measured Corneal values by using Scheimpflug tomography. Astigmatic power was converted to vectors. The agreement of astigmatism between an autorefractor (Topcon), cycloplegic refraction, subjective manifest refraction, front and back corneal astigmatism was measured overall and in each vector. The difference between Cycloplegic refraction and subjective manifest refraction was calculated in each vector axis. Factors were anticipated associated with discrepancy by using Multivariable Regression Analysis.Results: The maximum estimations of agreement were found berween autorefratometer and subjective manifest refraction in cylindrical power(Icc:0.703,P<0.026), cylindrical axis(Icc:0.943,P<0.0001) and astigmatic vestors of J0 (Icc:0.972,P<0.0001) and J45( Icc:827,P=0.006). The significant factors Associated With discrepancy between cyclorefraction and subjective manifest refraction in both vectors(J0 and J45) were Q-value(B Coefficient= -4.91, P<0.0001) (B Coefficient=1.01, P<0.0001), corneal astigmatism(B Coefficient= 0.66, P=0.001) (B Coefficient=0.11, P=0.001), Kmax(B Coefficient= -0.52, P<0.0001) (B Coefficient=0.07, P=0.02), IHA(B Coefficient=0.04, P=0.005) (B Coefficient= -0.03, P<0.0001). The significant associated factors for axis changes between cycloplegic refraction and subjective manifest refraction were cone location (B Coefficient= -33.34, P=0.001) and corneal astigmatism(B Coefficient= -0.1, P=0.04).Conclusion: Maximum agreement of subjective manifest refraction astigmatism is with auto refractometer in keratoconus patients, so it could be said that the result of the auto refractometer is the most appropriate starting point during subjective refraction in these patients. It can be predicted that the closer the keratoconus cone location relative to the center of the cornea and the lower the keratoconus patient's corneal astigmatism, the more the probability of axis changes by cycloplegic drop.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.