Kinematic analysis of upper limb reaching provides insight into the central nervous system control of movements. Until recently, kinematic examination of motor control has been limited to studies conducted in traditional research laboratories because motion capture equipment used for data collection is not easily portable and expensive. A recently developed markerless system, the Leap Motion Controller (LMC), is a portable and inexpensive tracking device that allows recording of 3D hand and finger position. The main goal of this study was to assess the concurrent reliability and validity of the LMC as compared to the Optotrak, a criterion-standard motion capture system, for measures of temporal accuracy and peak velocity during the performance of upper limb, visually-guided movements. In experiment 1, 14 participants executed aiming movements to visual targets presented on a computer monitor. Bland-Altman analysis was conducted to assess the validity and limits of agreement for measures of temporal accuracy (movement time, duration of deceleration interval), peak velocity, and spatial accuracy (endpoint accuracy). In addition, a one-sample t-test was used to test the hypothesis that the error difference between measures obtained from Optotrak and LMC is zero. In experiment 2, 15 participants performed a Fitts’ type aiming task in order to assess whether the LMC is capable of assessing a well-known speed-accuracy trade-off relationship. Experiment 3 assessed the temporal coordination pattern during the performance of a sequence consisting of a reaching, grasping, and placement task in 15 participants. Results from the t-test showed that the error difference in temporal measures was significantly different from zero. Based on the results from the 3 experiments, the average temporal error in movement time was 40±44 ms, and the error in peak velocity was 0.024±0.103 m/s. The limits of agreement between the LMC and Optotrak for spatial accuracy measures ranged between 2–5 cm. Although the LMC system is a low-cost, highly portable system, which could facilitate collection of kinematic data outside of the traditional laboratory settings, the temporal and spatial errors may limit the use of the device in some settings.
Regula rity measures [g'2] (AP, ML, VT, and vector), per step and per stride Harmonic Ratio {AP, ML, VT) Complexity and stability Range Average step and stride duration RMS Cadence (reported for PD in We iss 2014) Step symmetry Median number of steps for bout (n) Slope of domin ant frequency (psd/Hz) Refin ed composite multiscale e ntropy (RCME)-mean a nd variance Refined multiscale perm utation e ntropy (RMPE)-mean and variance Loca l dynamic stability {AP, ML, VT) Wolf's method Loca l dynamic stability per stride (AP, ML, VT) Wolf's method
Perceptual and visuomotor skills undergo considerable development from early childhood into adolescence; however, the concurrent maturation of these skills has not yet been examined. This study assessed visuomotor function and motion perception in a cross‐section of 226 typically‐developing children between 4 and 16 years of age. Participants were tested on three tasks hypothesized to engage the dorsal visual stream: threading a bead on a needle, marking dots using a pen, and discriminating form defined by motion contrast. Mature performance was reached between 8 and 12 years, with youngest maturation for kinematic measures for a reach‐to‐grasp task, and oldest maturation for a precision tapping task. Performance on the motion perception task shared no association with motor skills after controlling for age.
is an important issue with an ever greater impact on society. Wearable devices are now widely discussed as useful pragmatic tools in neurodegenerative diseases. Inertial wearables can quantify postural control and gait to provide useful digital biomarkers in dementia. Lack of standards and lack of access to large data sets are limiting the use of wearables in modern medicine.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.