The electrocoalescence of droplets plays a crucial role in various fields. However, studies on the effects of droplet radius on the electrocoalescence behaviors of droplets have not been conducted until now. In this work, the electrocoalescence behaviors of two unequally sized conducting droplets are investigated via molecular dynamics (MD) simulations. The influences of electric field strength and droplet radius on the electrocoalescence behaviors of two unequally sized droplets are investigated. When the electric field strength increases, the contact cone angle between the droplets increases, and the two droplets are more likely to partially coalesce and bounce. When the radius of the smaller droplet between the two droplets increases at the same electric field strength, the contact cone angle, daughter droplet size, and ions in the daughter droplet increase, whereas the critical electric field strength (E d ) for generating the daughter droplet decreases. Furthermore, the daughter droplet is ejected from the smaller droplet when the two droplets have different radii.
As smart materials, magnetorheological elastomers (MREs) have been broadly applied in the field of intelligent structures and devices. In order to mathematically represent the dynamic behavior in a wide range of strain amplitude, excitation frequency and magnetic field; a nonlinear model with a fractional element was developed for MREs in a linear viscoelastic regime. The identification of model parameters was realized through fitting experimental data of dynamic moduli measured in shear mode, and the identified parameters exhibited good repeatability and consistency to reflect the rationality of this nonlinear dynamic model. Considering material elasticity and viscosity, the dependence of model parameters on strain amplitudes and magnetic fields was analyzed to interpret the dynamics of MREs. The fitted results displayed an excellent agreement with the experimental results on the dependence of dynamic moduli on strain amplitudes and magnetic fields. Using the predictor-corrector approach, predicted results on the stress-strain hysteresis loop were calculated based on identified parameters to further validate the proposed model by comparing with experimental results and predicted results of the revised Bouc-Wen model. This proposed model is expected to facilitate the dynamic analysis and simulation of MRE based vibration systems with a high precision accuracy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.