In this paper, a nonlinear Bayesian filtering framework is proposed for the filtering of single channel noisy electrocardiogram (ECG) recordings. The necessary dynamic models of the ECG are based on a modified nonlinear dynamic model, previously suggested for the generation of a highly realistic synthetic ECG. A modified version of this model is used in several Bayesian filters, including the Extended Kalman Filter, Extended Kalman Smoother, and Unscented Kalman Filter. An automatic parameter selection method is also introduced, to facilitate the adaptation of the model parameters to a vast variety of ECGs. This approach is evaluated on several normal ECGs, by artificially adding white and colored Gaussian noises to visually inspected clean ECG recordings, and studying the SNR and morphology of the filter outputs. The results of the study demonstrate superior results compared with conventional ECG denoising approaches such as bandpass filtering, adaptive filtering, and wavelet denoising, over a wide range of ECG SNRs. The method is also successfully evaluated on real nonstationary muscle artifact. This method may therefore serve as an effective framework for the model-based filtering of noisy ECG recordings.
Abstract-In this letter, we propose the application of the generalized eigenvalue decomposition for the decomposition of multichannel electrocardiogram (ECG) recordings. The proposed method uses a modified version of a previously presented measure of periodicity and a phase-wrapping of the RR-interval, for extracting the "most periodic" linear mixtures of a recorded dataset. It is shown that the method is an improved extension of conventional source separation techniques, specifically customized for ECG signals. The method is therefore of special interest for the decomposition and compression of multichannel ECG, and for the removal of maternal ECG artifacts from fetal ECG recordings.
A three-dimensional dynamic model of the electrical activity of the heart is presented. The model is based on the single dipole model of the heart and is later related to the body surface potentials through a linear model which accounts for the temporal movements and rotations of the cardiac dipole, together with a realistic ECG noise model. The proposed model is also generalized to maternal and fetal ECG mixtures recorded from the abdomen of pregnant women in single and multiple pregnancies. The applicability of the model for the evaluation of signal processing algorithms is illustrated using independent component analysis. Considering the difficulties and limitations of recording long-term ECG data, especially from pregnant women, the model described in this paper may serve as an effective means of simulation and analysis of a wide range of ECGs, including adults and fetuses.
This paper presents efficient denoising and lossy compression schemes for electrocardiogram (ECG) signals based on a modified extended Kalman filter (EKF) structure. We have used a previously introduced two-dimensional EKF structure and modified its governing equations to be extended to a 17-dimensional case. The new EKF structure is used not only for denoising, but also for compression, since it provides estimation for each of the new 15 model parameters. Using these specific parameters, the signal is reconstructed with regard to the dynamical equations of the model. The performances of the proposed method are evaluated using standard denoising and compression efficiency measures. For denosing, the SNR improvement criterion is used, while for compression, we have considered the compression ratio (CR), the percentage area difference (PAD), and the weighted diagnostic distortion (WDD) measure. Several Massachusetts Institute of Technology-Beth Israel Deaconess Medical Center (MIT-BIH) ECG databases are used for performance evaluation. Simulation results illustrate that both applications can contribute to and enhance the clinical ECG data denoising and compression performance. For denoising, an average SNR improvement of 10.16 dB was achieved, which is 1.8 dB more than the next benchmark methods such as MABWT or EKF2. For compression, the algorithm was extended to include more than five Gaussian kernels. Results show a typical average CR of 11.37:1 with WDD << 1.73%. Consequently, the proposed framework is suitable for a hybrid system that integrates these algorithmic approaches for clean ECG data storage or transmission scenarios with high output SNRs, high CRs, and low distortions.
In this paper, the performance of traditional variance-based method for detection of epileptic seizures in EEG signals are compared with various methods based on nonlinear time series analysis, entropies, logistic regression,discrete wavelet transform and time frequency distributions.We noted that variance-based method in compare to the mentioned methods had the best result (100%) applied on the same database.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with đź’™ for researchers
Part of the Research Solutions Family.