Ultrasound (US) imaging, due to its capabilities in real-time imaging, portability, low-cost, and favorite safety, is frequently used as a diagnostic modality for visualization of different diseases. US imaging is...
A: Sparse-view x-ray micro computed tomography (micro-CT) reconstruction algorithms via total variation (TV) optimize the data without introducing notable noise and artifacts, resulting in significant scanning time reduction while maintaining image quality. However, due to the piecewise constant assumption for the image, a conventional TV minimization often suffers from patchy artifacts in reconstructed images. Moreover, for lack of directional gradient in TV some directional information are lost. To obviate these drawbacks, in this study we develop a penalized weighted least-square (PWLS) strategy for micro-CT sparse-view image reconstruction by incorporating an adaptive weighted total variation in combination with an adaptive weighted diagonal total variation (AwTV+AwDTV) penalty term. The AwTV considers the vertical and horizontal gradients while the AwDTV uses the diagonal gradients. The associated weights which are defined based on the anisotropic edge properties of an image, are expressed as an exponential function and can be adaptively adjusted by the amount of the difference between voxel intensities to preserve the edge details. To evaluate the presented (AwTV+AwDTV)-PWLS algorithm, both qualitative and quantitative studies were performed by computer simulations and micro-CT data experiments. The Shepp-Logan phantom for computer simulation and the micro-CT water phantom and a rat skull for micro-CT experiments are employed to perform image reconstruction. To evaluate the performance of AwTV+AwDTV algorithm, we compared it with TV and AwTV reconstruction algorithms. The simulation results show that the presented (AwTV+AwDTV)-PWLS algorithm can achieve the lowest RMSE and highest PSNR, SSIM and MTF for different number of projections as compared to the AwTV and conventional TV algorithms. The micro-CT data results confirmed the superiority of the proposed (AwTV+AwDTV) method to the AwTV and TV methods for different number of projections.
K: Computerized Tomography (CT) and Computed Radiography (CR); Data reduction methods; Image reconstruction in medical imaging
X-ray Computed Tomography (CT), e.g. clinical CT scanners, basically provides Linear Attenuation Coefficients (LACs) of objects under study by the means of algorithmic reconstruction of acquired views of attenuated X-ray passing through the samples in different angles around the imaged sample. Micro Computed Tomography (micro-CT) basically works the same as clinical CT. It provides volumetric information representing the inner structure of objects with a resolution in the micron range. LOTUS-inVivo is a micro-CT scanner dedicated to imaging of small animals and ex-vivo biological samples. In the present study the spatial resolution and Low Contrast Detectability (LCD) of LOTUS-inVivo scanner were evaluated using standard phantoms. We aimed to prove the capability of LOTUS-inVivo for small animal and ex-vivo biological samples imaging using the measured image quality parameters, i.e. spatial resolution and low contrast detectability. By the means of analysis of bar and LCD phantom images, the limiting resolution of LOTUS-inVivo micro-CT scanner was measured about 2.7 µm and has been shown that it’s capable of resolving sizes greater than 12.5 µm. Also, we concluded that LOTUS-inVivo is capable of discriminating tissues with 3% differences in contrast relative to the background, for 1 mm bar size. Thus, the provided technical characteristics in this study have made LOTUS-inVivo as a suitable tool for small animal imaging.
Mesoporous silica-coated bismuth nanoparticles (NPs) are dual-modal contrast agents that enable detection and quantization of cervical cancers at early stages using computed tomography (CT) and ultrasonography (US). Herein, the mesoporous...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.