<p>The popularity, great influence and huge importance made wireless indoor localization has a unique touch, as well its wide successful on positioning and tracking systems for both human and assists also contributing to take the lead from outdoor systems in the scope of the recent research works. In this work, we will attempt to provide a survey of the existing indoor positioning solutions and attempt to classify different its techniques and systems. Five typical location predication approaches (triangulation, fingerprinting, proximity, vision analysis and trilateration) are considered here in order to analysis and provide the reader a review of the recent advances in wireless indoor localization techniques and systems to have a good understanding of state of the art technologies and motivate new research efforts in this promising direction. For these reasons, existing wireless localization position systems and location estimation schemes are reviewed. We also made a comparison among the related techniques and systems along with conclusions and future trends to identify some possible areas of enhancements. </p>
There are many applications of two-phase hybrid stepping motor (2Ph-HSM) system. The robotic grinding system (RGS) one of these applications. In this work, under the title variable speed control. The aim is Simulink the 2Ph-HSM in RGS with a proportional-integral controller (PIC) and optimization unit such as Genetic Algorithm (GA) which tuning PIC as (GA_PIC) to improve the RGS action by improving the parameters of PIC. Also comparing the act of PIC and GA_PIC to see which state is the best. The simulation results of this work show the GA_PIC is the best that comparative with PIC.
<p><span>The search of FLC_PID controller for TCP/AQM Wireless Networks, to deal with congestion for Internet users and to get good performance and capabilities of TCP / IP networks. Neglect of controlling the network delay and the number of continuous users that leads to a problem in the transmission process. Recently, automatic control units are adapted to solve this problem with the difficulty of controlling congestion in the presence of wireless links. This modest research presents one of the traditional PID controller methods with fuzzy logic so that wireless networks and congestion can be controlled by various configurations. The proposed methods were simulated with the required comparisons in the adoption of nonlinear systems to determine the best performance and it was found that the use of the Fuzzy logic control can achieve the best performance (reducing the delay time of delivering packets and packets loss). The simulation of the current work shows through its results the possibility of controlling the behavior of the system and through testing the balance when changed with time delay through the impact of communication time and its relationship with the stability of the work of the system.</span></p>
The life development and increase the number of internet users imposed an increase in data circulating on the internet network and then make the network more congestion. As a result of all this, some problems arose such as time delay in packets delivery, loss of packets, and exceed the buffer capacity for the middle routers. To overcome those problems, transmission control protocol and active queue management (TCP/AQM) have been used. AQM is the main approach used to control congestion and overcome those problems to improve network performance. This work proposes to use the proportional-integral (PI) controller with a genetic algorithm (GA) as an active queue manager for routers of the Internet. The simulation results show a good performance for managing the congestion with using proportional-integral genetic algorithm (GA-PI) controller better than the PI controller.
Internet networks are becoming more crowded every day due to the rapid development of modern life, which causes an increase in the demand for data circulating on the Internet. This creates several problems, such as buffer overflow of intermediate routers, and packet loss and time delay in packet delivery. The solution to these problems is to use a TCP/AQM system. The simulation results showed that there were differences in performance between the different controllers used. The proposed methods were simulated along with the required conditions in nonlinear systems to determine the best performance. It was found that the use of optimization Department of Electro-mechanical Engineering, University of Technology - Iraq tools (GA, FL) with a controller could achieve the best performance. The simulation results demonstrated the ability of the proposed methods to control the behavior of the system. The controller systems were simulated using Matlab/Simulink. The simulation results showed that the performance was better with the use of GA-PIDC compared to both FL-PIDC and PIDC in terms of stability time, height, and overrun ratio for a network with a variable queue that was targeted for comparison. The results were: the bypass ratio was 0, 3.3 and 21.8 the settling time was 0.002, 0.055, and 0.135; and the rise time was 0.001, 0.004 and 0.008 for GA-PIDC, FL-PIDC and PIDC, respectively. These results made it possible to compare the three control techniques.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.