Purpose Correct differentiation between malignant and benign incidentally found cystic renal lesions has critical implications for patient management. In several studies contrast-enhanced ultrasound (CEUS) showed higher sensitivity with respect to the accurate characterization of these lesions compared to MRI, but the cost-effectiveness of CEUS has yet to be investigated. The aim of this study was to analyze the cost-effectiveness of CEUS as an alternative imaging method to MRI for the characterization of incidentally found cystic renal lesions. Materials and Methods A decision model including the diagnostic modalities MRI and CEUS was created based on Markov simulations estimating lifetime costs and quality-adjusted life years (QALYs). The recent literature was reviewed to obtain model input parameters. The deterministic sensitivity of diagnostic parameters and costs was determined and probabilistic sensitivity analysis using Monte-Carlo Modelling was applied. Willingness-to-pay (WTP) was assumed to be $ 100 000/QALY. Results In the base-case scenario, the total costs for CEUS were $9654.43, whereas the total costs for MRI were $9675.03. CEUS resulted in an expected effectiveness of 8.06 QALYs versus 8.06 QALYs for MRI. Therefore, from an economic point of view, CEUS was identified as an adequate diagnostic alternative to MRI. Sensitivity analysis showed that results may vary if CEUS costs increase or those of MRI decrease. Conclusion Based on the results of the analysis, the use of CEUS was identified as a cost-effective diagnostic strategy for the characterization of incidentally found cystic renal lesions.
Neuroendocrine tumors (NETs) are relatively rare neoplasms arising from the hormone-producing neuroendocrine system that can occur in various organs such as pancreas, small bowel, stomach and lung. As the majority of these tumors express somatostatin receptors (SSR) on their cell membrane, utilization of SSR analogs in nuclear medicine is a promising, but relatively costly approach for detection and localization. The aim of this study was to analyze the cost-effectiveness of 68Ga-DOTA-TATE PET/CT (Gallium-68 DOTA-TATE Positron emission tomography/computed tomography) compared to 111In-pentetreotide SPECT/CT (Indium-111 pentetreotide Single Photon emission computed tomography/computed tomography) and to CT (computed tomography) alone in detection of NETs. A decision model on the basis of Markov simulations evaluated lifetime costs and quality-adjusted life years (QALYs) related to either a CT, SPECT/CT or PET/CT. Model input parameters were obtained from publicized research projects. The analysis is grounded on the US healthcare system. Deterministic sensitivity analysis of diagnostic parameters and probabilistic sensitivity analysis predicated on a Monte Carlo simulation with 30,000 reiterations was executed. The willingness-to-pay (WTP) was determined to be $ 100,000/QALY. In the base-case investigation, PET/CT ended up with total costs of $88,003.07 with an efficacy of 4.179, whereas CT ended up with total costs of $88,894.71 with an efficacy of 4.165. SPECT/CT ended up with total costs of $89,973.34 with an efficacy of 4.158. Therefore, the strategies CT and SPECT/CT were dominated by PET/CT in the base-case scenario. In the sensitivity analyses, PET/CT remained a cost-effective strategy. This result was due to reduced therapy costs of timely detection. The additional costs of 68Ga-DOTA-TATE PET/CT when compared to CT alone are justified in the light of potential savings in therapy costs and better outcomes.
Fusion imaging depicts an innovative technique that facilitates combining assets and reducing restrictions of advanced ultrasound and cross-sectional imaging. The purpose of the present retrospective study was to evaluate the role of fusion imaging for assessing hepatic and renal lesions. Between 02/2011–08/2020, 92 patients in total were included in the study, of which 32 patients had hepatic lesions, 60 patients had renal lesions. Fusion imaging was technically successful in all patients. No adverse side effects upon intravenous (i.v.) application of SonoVue® (Bracco, Milan, Italy) were registered. Fusion imaging could clarify all 11 (100%) initially as indeterminate described hepatic lesions by computed tomography/magnetic resonance imaging (CT/MRI). Moreover, 5/14 (36%) initially suspicious hepatic lesions could be validated by fusion imaging, whereas in 8/14 (57%), malignant morphology was disproved. Moreover, fusion imaging allowed for the clarification of 29/30 (97%) renal lesions initially characterized as suspicious by CT/MRI, of which 19/30 (63%) underwent renal surgery, histopathology revealed malignancy in 16/19 (84%), and benignity in 3/19 (16%). Indeterminate findings could be elucidated by fusion imaging in 20/20 (100%) renal lesions. Its accessibility and repeatability, even during pregnancy and in childhood, its cost-effectiveness, and its excellent safety profile, make fusion imaging a promising instrument for the thorough evaluation of hepatic and renal lesions in the future.
Bosniak 2F renal cystic lesions feature morphologic characteristics between Bosniak I and III categories, the majority of which remain benign. However, a minor part of Bosniak 2F lesions may progress to malignancy. The purpose of this study was to assess Bosniak 2F cystic lesions during follow-up examinations by CEUS. One-hundred-and-twelve out of 364 patients with Bosniak 2F lesions underwent follow-up CEUS examinations between February 2008 and February 2020. Twelve out of 364 patients underwent renal surgery without follow-up CEUS. The progression rate of Bosniak 2F renal lesions detected by CEUS accounted for 7.1% (8/112 patients) after a mean of 12.9 months. The first follow-up CEUS revealed 75% of progressions (6/8), the remaining 25% (2/8) of progressions were detected during second follow-up CEUS. Underlying clear-cell renal cell carcinoma was histopathologically validated in 5/8 progressive complex cystic renal lesions. Stable sonomorphologic features were observed in 92.1% (104/112 patients). CEUS depicts a promising diagnostic imaging modality in the diagnostic work-up and follow-up of complex renal cystic lesions at higher spatial and temporal resolutions than CT or MRI. Its excellent safety profile, its easy and repeatable accessibility, and low financial costs render CEUS an attractive and powerful alternative imaging tool for monitoring complex renal cystic lesions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.