According to the architectural requirements, the roof structure of a large-span gymnasium adopts the suspen-dome structure. In the scheme selection stage of the pre-stressed cable-strut system at the bottom part of the suspen-dome structure, a Levy-type scheme and a Loop-free scheme are established. The finite element models are established, and the static analysis under the design loads, the whole process analysis of load-displacement, and the dynamic response analysis after accidental cable break are carried out. The architectural expression of the two schemes are discussed. The component material consumption, the structural stiffness, the tension distribution characteristics, and the static bearing capacity of the two schemes are discussed. The failure mode and the progressive collapse resistance of the two schemes after accidental cable break are also discussed. The results show that the Loop-free scheme requires significantly less in terms of component material consumption than the Levy-type scheme. The static failure mode of the two schemes is strength failure, but the Loop-free scheme has greater bearing capacity. The Loop-free scheme has greater structural stiffness, lower cable forces, and uniformly distributed cable forces in each layer, and lower stress on the top reticulated shell members. Neither of the two schemes experience progressive collapse after accidental cable break. Due to the rupture in the loop cable of the Levy-type scheme, the rigidity of the rear region decreases greatly, and the cable force loss is large. On the contrary, internal force redistribution occurs in the Loop-free cable scheme and the cable force loss is not obvious, hence the progressive collapse resistance is better than that of the Levy-type scheme.
A double-sided thin steel plate shear wall filled with rigid polyurethane foam (SWR) is proposed. A quasi-static monotonic loading test and quasi-static cycling loading test on shear behavior and the energy dissipation capacity of the SWR were carried out. Four kinds of test specimens, including the pure steel frames, the steel frame with double-sided thin steel plates, the SWR, and the SWR with an open hole, were tested. The results showed that compared with the pure steel frame, the erection of thin steel plates on both sides enhances the shear bearing capacity, initial shear stiffness, and energy consumption capacity. It turns out that the rigid foam polyurethane (RPUF) significantly increases the shear performance of the thin steel plate shear wall. The main reason for this is that the bond effect and support effect of the RPUF delay the out-of-plane buckling of thin steel plates and improve shear performance and energy dissipation capacity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.