Introduction:
Aerosols and droplets contaminated with bacteria and blood are produced during ultrasonic scaling. Measures to control aerosol contamination in dental clinics are recommended by the Centers for Disease Control and Prevention. This study aimed to evaluate the efficacy of preprocedural boric acid (BA) mouthrinse in reducing bacterial contamination in dental aerosols generated during ultrasonic scaling.
Materials and Methods:
This was a randomised clinical trial in 90 systemically healthy subjects (25-55 yrs) diagnosed with chronic periodontitis who were allocated into three groups of 30 subjects each to receive, Group A - 0.12% chlorhexidine (CHX), Group B - 0.75% BA and Group C-water, as a preprocedural rinse for 1 min. The aerosol generated while performing ultrasonic scaling for 30 min was collected at three locations on blood agar plates. Incubation of the blood agar plates at 37°C for next 48 h for aerobic culture was performed and subsequently colony-forming units (CFUs) were counted.
Results:
CFUs in Group A were significantly reduced compared with Group B (
P
< 0.001). When we compare CFUs in all the three groups, CFUs in Groups A and B were statistically significantly reduced compared with Group C (
P
< 0.001). Furthermore, it was also observed that the assistant's chest area had lowest CFUs whereas patient's chest area had highest.
Conclusion:
This study recommends routine use of preprocedural mouthrinse as a measure to reduce bacterial aerosols generated during ultrasonic scaling and that 0.12% CHX gluconate is more effective than 0.75% BA mouthwash in reducing CFUs count.
Background:
Every year, around 2 million people suffer from hospital-acquired infections worldwide. Aerosols are produced while performing ultrasonic scaling. They are potential source of infection and cross contamination. It can result in spread of several infections including hepatitis, HIV, SARS CoV 2, etc. Preprocedural rinse before scaling is considered an effective measure to reduce the microbial load in aerosols.
Materials and Methods:
This study was a triple-blinded randomized controlled trial performed on 90 participants diagnosed with chronic periodontitis. Random allocation of participants into three groups, i.e., Group-1, Group-2, and Group-3, was done, wherein 0.12% chlorhexidine (CHX), 1.5% hydrogen peroxide (HP), and distilled water (DW) were used, respectively, as preprocedural mouthrinse. The participants of each group were instructed to perform mouthrinse for 60 s before the start of ultrasonic scaling sessions. Blood agar plates were kept at three locations, i.e., operator's chest area, patient's chest area, and assistant's chest area for aerosol collection after scaling. Colony-forming units (CFUs) were counted for microbiological analysis.
Results:
Least number of CFUs was found in the CHX group, followed by HP and DW groups. Location wise, the patient's chest area had the highest CFU count and the least was at the assistant's chest area. CFU count between the groups was statistically significant.
Conclusion:
Preprocedural rinse using HP can effectively be used as a method to reduce dental aerosols generated during ultrasonic scaling.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.